Step 4: Installing Anti-Tip Device - Thermador PRG364GDH Installation Manual

30" and 36" models
Hide thumbs Also See for PRG364GDH:
Table of Contents

Advertisement

Available languages

Available languages

Step 4: Installing Anti-Tip
Device
For all 30" and 36" ranges,
installed as per these instructions.
WARNING — RANGE TIPPING
HAZARD
All ranges can tip and injury can result. To
prevent accidental tipping of the range,
attach it to the floor, wall or cabinet by
installing the Anti-Tip Device supplied.
A risk of tip-over may exist if the appliance
is not installed in accordance with these
instructions.
If the range is pulled away from the wall for
cleaning, service or any other reason,
ensure that the Anti-Tip Device is properly
reengaged when the range is pushed back
against the wall. In the event of abnormal
usage (such as a person standing, sitting,
or leaning on an open door), failure to take
this precaution can result in tipping of the
range. Personal injury might result from
spilled hot liquids or from the range itself.
WARNING
HAZARD
Use extreme caution when drilling holes
into the wall or floor. There may be con-
cealed electrical wires located behind the
wall or under the floor.
Identify the electrical circuits that could be
affected by the installation of the Anti-Tip
Device, then turn off power to these cir-
cuits.
Failure to follow these instructions may
result in electrical shock or other personal
injury.
WARNING:
All Ranges can tip
Injury to Persons could result
Install Anti-Tip Device
See Installation Instructions
English 10
an anti-tip device must be
ELECRICAL SHOCK
ATTENTION — PROPERTY DAMAGE
Contact a qualified installer or contractor to determine
the proper method for drilling holes through the wall or
floor material (such as ceramic tile, hardwood, etc.)
Do not slide the range across an unprotected floor.
Failure to follow these instructions may result in
damage to wall or floor coverings.
Tools Needed for Installation of Anti-Tip
Device:
Screwdriver, Phillips
Drill, electric or hand
Measuring tape or ruler
1/8" drill bit (wood or metal wall or floor)
3/16" carbide-tipped masonry drill bit (concrete or
concrete block wall or floor)
3/16" anchors, drywall or concrete, 4 each (not
required if mounting bracket is being attached to solid
wood or metal)
Hammer
Pencil or other marker
30" and 36" Ranges
See Figure 6 and Figure 7.
Thermador
Qty
Service Part No.
415078
647936
Important Installation Information:
The anti-tip bracket may be attached to a solid wood
cabinet having a minimum wall thickness of 3/4".
The thickness of the wall or floor may require use of
longer screws, available at your local hardware store.
In all cases, at least two (2) of the bracket mounting
screws must be fastened to solid wood or metal.
Use appropriate anchors when fastening the mounting
bracket to any material other than hard-wood or metal.
Description
Screw, Phillips,
4
#10 x 1-1/2"
Anti-Tip Bracket,
1
Floor-Mounted

Advertisement

Table of Contents
loading

Table of Contents