Technical specifications

Refrigeration pressure data
§ Water regulating valve is factory set at 300 ±10 PSIG (2068.4 ± 69 kPA) head pressure.
§ Readings within 10% of table values should be considered normal.
Compressor data
Air-cooled
Ambient air temperature
Amperage
High-side pressure (PSIG)
Low-side pressure (PSIG)
Locked rotor amps
Condenser water usage:
Gearmotor data
Gearmotor current
50 F/10 C
2.25
105
18.5
230 V: 18.2A
@90 F/70F: 0.56 gal/min
230 V/50 Hz
1.3A (nominal)
70 F/21.1 C
90 F/32.2 C
2.36
2.46
142
190
21
25
MC_414A, MF_414A R290 230 V/50 Hz Ice Machines
110 F/43.3C
2.57
245
27
5