EN 138
8.
EBJ1.0U
0 6 2 5 9 6 I+
USE CURSOR KEYS TO HIGHLIGHT
USE MENU KEY TO SELECT
USE STATUS KEY TO RETURN
Use the Cursor Up-Down button to highlight the selection.
Press the Cursor Right button to make the selection. In the
second menu:
MANUAL CONVERGENCE WITHOUT VIDEO means that
the screen behind the adjustment grid will be blank.
MANUAL CONVERGENCE WITH VIDEO displays the
applied video behind the adjustment grid.
RESTORE FACTORY loads the values from the last saved
convergence alignment.
RESTORE DEFAULT loads values from the ROM on the
ACS Microprocessor.
RESTORE FACTORY or RESTORE DEFAULT will
overwrite all nine convergence modes.
If the ACS module has been changed, there may not be data in
the NVM for RESTORE FACTORY. The RESTORE DEFAULT
settings will then be loaded.
An internally generated grid will be displayed in the
Convergence mode as shown on the following page. The
shaded area is the visible screen area. Horizontal lines A and
M are displayed on the top and bottom edge of the visible
screen area. Lines 1 and 15 are also displayed on the left and
right edge of the visible screen area. Vertical line 0 is adjustable
although it is not visible.
Alignments
MENU
CURSOR KEYS TO ADJUST
MENU TO CHANGE
STEP SIZE
I+ TO RETURN
CURSOR RIGHT TO SELECT
POWER OFF TO EXIT CONVERGENCE
CONVERGENCE ADJUSTMENTS
SENSOR TEST
1
2
3
4
Figure 8-2 Convergence menus
CURSOR KEYS TO
NAVIGATE
MENU TO ADJUST
I+ TO RETURN
I+
MANUAL CONVERGENCE WO VIDEO
MANUAL CONVERGENCE W VIDEO
RESTORE FACTORY
RESTORE DEFAULTS
CURSOR RIGHT TO SELECT
I+ TO RETURN
I+
SENSORS NOT VERIFIED
AT LOCATIONS______
MENU TO TEST AGAIN
I+ TO RETURN
SENSORS OK
I+ TO RETURN
0
1
A
B
C
D
E
F
G
H
I
J
K
L
M
8.5.6
Single Tube Replacement Convergence
If a single tube has been replaced, it is not necessary to do a
Major Convergence alignment.
1. Enter the Convergence mode and select the adjustment
needed.
2. Select "Red to Green", for example if the Red tube has
been replaced.
3. Adjust the centring rings on the CRT to centre the Red
pattern onto the Green pattern.
4. Starting with the centreline, adjust the Red icon onto the
Green pattern.
Best results are obtained when navigating from left to right.
Two or three passes may be necessary to obtain satisfactory
results.
CURSOR RIGHT
I+
GREEN
RED TO GREEN
BLUE TO GREEN
GREEN TO RED
BLUE TO RED
SP RED
SP BLUE
MP RED
MP BLUE
STORE
I+
MENU TO SAVE DATA
I+ TO RETURN
MENU TO SAVE DATA
I+ TO RETURN
2
3
4
5
6
7
8
9
10 11 12 13 14 15
Figure 8-3 Convergence grid
G_15860_053.eps