Test Run; Bacnet Communication Settings; Indoor Unit Device Information Settings - Toshiba Carrier BMS-IFBN1281U-UL Service Manual

Hide thumbs Also See for Carrier BMS-IFBN1281U-UL:
Table of Contents

Advertisement

BN interface
9

Test run

To perform test run of the BN interface, BACnet communication settings and the equipment data of the connected indoor units
are required.
 Settings, descriptions and configuration method before test run
Device
Outdoor unit
Address
Indoor unit
Address
IP address
BACnet
identification
number
BN interface
Indoor unit
device
configuration

9-1. BACnet Communication Settings

Set the IP address of the BN interface and the device object instance number of the BACnet communications. These setting
can set from Engineering Tool. (page 91)

9-2. Indoor Unit Device Information Settings

Obtain the equipment data of the indoor unit that is controlled by the BN interface from the indoor unit via the Uh Line
communication cable.
Preparing to set up equipment data in the indoor unit
• Central Control address must be set in the indoor unit you want to control.
For information on how to set the address, refer to the installation manual of each indoor unit.
• Turn on all indoor and outdoor units. Set up as follows, waiting 10 minutes after turning on all the units.
86
-EN
Item
Line address
Central control address
Line address
Unit address
Group address
IP address
Network mask
Instance number of BACnet
Device object
Model
Model name
horse power
Serial number
Line address
Unit address
Central control address
Group address
DN code setting
Range of operating modes
Range of wind speeds
Range of flaps
Range of temperature
settings
Range of ventilation amount
Range of ventilation modes
Any ventilation operation
Any save operation
Factory default
Configuration method, device, software
settings
1
DIP switch of outdoor unit board
Wired remote controller (except simple
99/Un
wired remote controller)
99/Un
Wired remote controller (except simple
wired remote controller)
99/Un
Or automatic address setting from the
outdoor unit
99/Un
192.168.1.100
Setting File Creation Software
255.255.255.0
(See "Section 9-1.")
Setting is necessary if there are any
100
changes from the initial values
Depends on the model
Depends on the model
Depends on the model
Depends on the model
Depend on Unit(s)
Depend on Unit(s)
Depend on Unit(s)
Depend on Unit(s)
Automatic configuration in the air-
-
conditioning search mode of the BN
interface
Depends on the model
(See "Section 9-2.")
Depends on the model
Depends on the model
Depends on the model
Depends on the model
Depends on the model
Depends on the model
Depends on the model