3) Outlet directions
Select the appropriate number of outlet directions according to the installation conditions.
Function number
22
4) Vertical airflow direction range control
To prevent draft, change the setting to "Upward" (01).
Note that the airflow in certain usage conditions may leave the ceiling dirty. In such cases, the use of
the optional Panel spacer is recommended.
Function number
23
9-2. Contents of function setting
Setting value
00
01
Setting value
00
01
Swing scope (standard)
Swing scope (upward)
- 70 -
Setting description
4-way
3-way
Setting description
Standard
Upward
Ceiling
Factory setting
Factory setting
9. Function settings