Fujitsu AOU48RGLX Design & Technical Manual page 22

Hide thumbs Also See for AOU48RGLX:
Table of Contents

Advertisement

¢ Model: AUU48RGLX
AFR
CFM
°FDB
64
°FWB
54
°FDB
TC
SHC
kBtu
-5
35.71
28.50
5
35.58
28.40
15
35.22
26.73
32
35.04
26.33
41
34.74
26.39
50
34.41
26.51
59
34.47
26.48
67
35.70
26.61
77
37.17
27.77
87
38.31
27.93
95
37.92
28.05
104
34.86
26.48
115
26.64
22.52
3
AFR
m
°CDB
17.8
°CWB
12.2
TC
SHC
°CDB
kW
-20.6
10.47
8.35
-15.0
10.43
8.32
-10.0
10.32
7.84
0.0
10.27
7.72
5.0
10.18
7.73
10.0
10.08
7.77
15.0
10.10
7.76
19.4
10.46
7.80
25.0
10.89
8.14
30.0
11.23
8.19
35.0
11.11
8.22
40.0
10.22
7.76
46.1
7.81
6.60
4-1. Cooling capacity
70
60
IP
TC
SHC
IP
TC
kW
kBtu
kW
1.77
39.81
28.66
1.80
42.52
1.80
39.66
28.56
1.84
42.36
1.89
39.24
26.89
1.93
41.93
1.95
39.03
26.48
1.99
41.69
2.00
38.70
26.55
2.03
41.33
2.06
38.34
26.67
2.09
40.94
2.15
38.40
26.64
2.18
41.03
2.52
39.78
26.77
2.56
42.48
3.00
41.43
27.93
3.04
44.25
4.19
42.69
28.08
4.26
45.59
4.59
42.24
28.21
4.66
45.12
4.71
38.82
26.64
4.78
41.46
3.58
29.67
22.65
3.64
31.71
/h
21.1
15.6
IP
TC
SHC
IP
TC
kW
1.77
11.67
8.40
1.80
12.46
1.80
11.62
8.37
1.84
12.42
1.89
11.50
7.88
1.93
12.29
1.95
11.44
7.76
1.99
12.22
2.00
11.34
7.78
2.03
12.11
2.06
11.24
7.82
2.09
12.00
2.15
11.25
7.81
2.18
12.02
2.52
11.66
7.84
2.56
12.45
3.00
12.14
8.19
3.04
12.97
4.19
12.51
8.23
4.26
13.36
4.59
12.38
8.27
4.66
13.22
4.71
11.38
7.81
4.78
12.15
3.58
8.70
6.64
3.64
9.29
Indoor temperature
75
80
63
67
SHC
IP
TC
SHC
kBtu
kW
kBtu
kW
31.23
1.82
45.23
33.77
1.83
31.12
1.85
45.06
33.65
1.87
29.26
1.95
44.58
31.67
1.96
28.82
2.01
44.34
31.16
2.03
28.90
2.05
43.95
31.26
2.07
29.01
2.12
43.56
31.38
2.13
29.01
2.21
43.65
31.38
2.23
29.14
2.58
45.18
31.54
2.61
30.41
3.08
47.07
32.89
3.10
30.58
4.30
48.51
33.08
4.34
30.74
4.71
48.00
33.24
4.75
29.01
4.83
44.10
31.38
4.88
24.68
3.67
33.72
26.67
3.70
Indoor temperature
23.9
26.7
17.2
19.4
SHC
IP
TC
SHC
kW
kW
9.15
1.82
13.26
9.90
1.83
9.12
1.85
13.21
9.86
1.87
8.58
1.95
13.07
9.28
1.96
8.45
2.01
13.00
9.13
2.03
8.47
2.05
12.88
9.16
2.07
8.50
2.12
12.77
9.20
2.13
8.50
2.21
12.79
9.20
2.23
8.54
2.58
13.24
9.24
2.61
8.91
3.08
13.80
9.64
3.10
8.96
4.30
14.22
9.70
4.34
9.01
4.71
14.07
9.74
4.75
8.50
4.83
12.92
9.20
4.88
7.23
3.67
9.88
7.82
3.70
- 16 -
1,236
85
71
IP
TC
SHC
IP
TC
kBtu
kW
kBtu
47.94
33.64
1.85
50.65
47.76
33.52
1.89
50.46
47.28
31.54
1.99
49.95
47.01
31.04
2.05
49.65
46.59
31.13
2.09
49.23
46.17
31.26
2.16
48.78
46.26
31.26
2.25
48.87
47.91
31.41
2.63
50.61
49.89
32.77
3.14
52.71
51.42
32.95
4.38
54.33
50.88
33.11
4.80
53.76
46.77
31.26
4.93
49.41
35.76
26.58
3.75
37.77
2,100
29.4
21.7
IP
TC
SHC
IP
TC
kW
14.05
9.86
1.85
14.84
14.00
9.82
1.89
14.79
13.86
9.24
1.99
14.64
13.78
9.10
2.05
14.55
13.65
9.12
2.09
14.43
13.53
9.16
2.16
14.30
13.56
9.16
2.25
14.32
14.04
9.21
2.63
14.83
14.62
9.60
3.14
15.45
15.07
9.66
4.38
15.92
14.91
9.70
4.80
15.76
13.71
9.16
4.93
14.48
10.48
7.79
3.75
11.07
90
73
SHC
IP
kW
35.85
1.87
35.72
1.90
33.61
2.01
33.08
2.06
33.17
2.12
33.30
2.18
33.30
2.27
33.46
2.66
34.90
3.17
35.12
4.43
35.28
4.85
33.30
4.98
28.30
3.78
32.2
22.8
SHC
IP
kW
10.51
1.87
10.47
1.90
9.85
2.01
9.70
2.06
9.72
2.12
9.76
2.18
9.76
2.27
9.81
2.66
10.23
3.17
10.29
4.43
10.34
4.85
9.76
4.98
8.30
3.78
4. Capacity table

Advertisement

Table of Contents
loading

Table of Contents