Fujitsu AOU48RGLX Design & Technical Manual page 25

Hide thumbs Also See for AOU48RGLX:
Table of Contents

Advertisement

¢ Model: AUU42RGLX
AFR
CFM
°FDB
°FDB
°FWB
-5
-7
5
3
14
12
17
21
23
19
32
28
41
37
47
43
50
47
59
50
3
AFR
m
°CDB
°CDB
°CWB
-20.6
-21.7
-15.0
-16.1
-10.0
-11.1
-8.3
-6.1
-5.0
-7.2
0.0
-2.2
5.0
2.8
8.3
6.1
10.0
8.3
15.0
10.0
¢ Model: AUU48RGLX
AFR
CFM
°FDB
°FDB
°FWB
-5
-7
5
3
14
12
17
21
23
19
32
28
41
37
47
43
50
47
59
50
AFR
3
m
°CDB
°CDB
°CWB
-20.6
-21.7
-15.0
-16.1
-10.0
-11.1
-8.3
-6.1
-5.0
-7.2
0.0
-2.2
5.0
2.8
8.3
6.1
10.0
8.3
15.0
10.0
4-2. Heating capacity
60
65
TC
IP
TC
kBtu/h
kW
kBtu/h
34.89
4.21
34.05
37.81
4.21
36.90
42.37
4.21
41.37
43.01
4.21
41.99
45.55
4.21
44.48
48.89
4.21
47.73
52.04
4.21
50.81
53.55
4.21
52.29
54.84
4.20
53.52
55.91
4.17
54.59
/h
15.6
18.3
TC
IP
TC
kW
kW
10.23
4.21
9.98
11.08
4.21
10.81
12.42
4.21
12.12
12.61
4.21
12.31
13.35
4.21
13.04
14.33
4.21
13.99
15.25
4.21
14.89
15.69
4.21
15.33
16.07
4.20
15.69
16.39
4.17
16.00
60
65
TC
IP
TC
kBtu/h
kW
kBtu/h
35.09
4.47
34.25
37.89
4.47
36.97
42.84
4.48
41.83
44.70
4.48
43.64
48.22
4.47
47.06
51.85
4.48
50.63
55.98
4.49
54.63
57.75
4.49
56.38
59.22
4.47
57.81
60.62
4.43
59.16
/h
15.6
18.3
TC
IP
TC
kW
kW
10.29
4.47
10.04
11.10
4.47
10.84
12.56
4.48
12.26
13.10
4.48
12.79
14.13
4.47
13.79
15.20
4.48
14.84
16.41
4.49
16.01
16.93
4.49
16.52
17.36
4.47
16.94
17.77
4.43
17.34
Indoor temperature
70
IP
TC
IP
kW
kBtu/h
kW
4.29
33.23
4.39
4.30
36.01
4.39
4.30
40.36
4.38
4.30
40.97
4.38
4.29
43.38
4.38
4.30
46.56
4.38
4.30
49.55
4.38
4.30
51.00
4.39
4.28
52.23
4.37
4.26
53.24
4.35
Indoor temperature
21.1
IP
TC
IP
kW
4.29
9.74
4.39
4.30
10.56
4.39
4.30
11.83
4.38
4.30
12.01
4.38
4.29
12.71
4.38
4.30
13.65
4.38
4.30
14.52
4.38
4.30
14.95
4.39
4.28
15.31
4.37
4.26
15.60
4.35
Indoor temperature
70
IP
TC
IP
kW
kBtu/h
kW
4.57
33.42
4.66
4.57
36.09
4.66
4.57
40.82
4.66
4.57
42.58
4.66
4.57
45.89
4.66
4.57
49.41
4.66
4.57
53.29
4.67
4.58
55.00
4.67
4.56
56.41
4.65
4.53
57.72
4.61
Indoor temperature
21.1
IP
TC
IP
kW
4.57
9.80
4.66
4.57
10.58
4.66
4.57
11.96
4.66
4.57
12.48
4.66
4.57
13.45
4.66
4.57
14.48
4.66
4.57
15.62
4.67
4.58
16.12
4.67
4.56
16.53
4.65
4.53
16.92
4.61
- 19 -
1,177
72
75
TC
IP
TC
kBtu/h
kW
kBtu/h
32.39
4.47
31.58
35.10
4.47
34.22
39.35
4.47
38.34
39.95
4.47
38.92
42.31
4.47
41.24
45.40
4.47
44.23
48.32
4.47
47.10
49.74
4.47
48.45
50.91
4.46
49.61
51.91
4.43
50.59
2,000
22.2
23.9
TC
IP
TC
kW
kW
9.49
4.47
9.26
10.29
4.47
10.03
11.53
4.47
11.24
11.71
4.47
11.41
12.40
4.47
12.09
13.30
4.47
12.96
14.16
4.47
13.80
14.58
4.47
14.20
14.92
4.46
14.54
15.21
4.43
14.83
1,236
72
75
TC
IP
TC
kBtu/h
kW
kBtu/h
32.58
4.75
31.75
35.17
4.75
34.28
39.78
4.76
38.78
41.49
4.76
40.43
44.76
4.75
43.60
48.16
4.76
46.93
51.98
4.77
50.63
53.63
4.77
52.25
54.97
4.75
53.56
56.28
4.71
54.85
2,100
22.2
23.9
TC
IP
TC
kW
kW
9.55
4.75
9.31
10.31
4.75
10.05
11.66
4.76
11.36
12.16
4.76
11.85
13.12
4.75
12.78
14.11
4.76
13.76
15.23
4.77
14.84
15.72
4.77
15.31
16.11
4.75
15.70
16.50
4.71
16.07
4. Capacity table
IP
kW
4.56
4.57
4.56
4.56
4.56
4.56
4.56
4.56
4.55
4.50
IP
4.56
4.57
4.56
4.56
4.56
4.56
4.56
4.56
4.55
4.50
IP
kW
4.85
4.85
4.85
4.85
4.85
4.85
4.86
4.86
4.85
4.78
IP
4.85
4.85
4.85
4.85
4.85
4.85
4.86
4.86
4.85
4.78

Advertisement

Table of Contents
loading