Technical Data - Tronic 86620 Operating Instructions Manual

Power inverter
Table of Contents

Advertisement

Available languages

Available languages

This device suitable only for use indoors.
Risk of fire!
• Do not use the device near hot surfaces.
• Do not locate the device in places exposed to
direct sunlight, Otherwise, it may overheat and
become irreparably damaged. Do not operate
the device in a vehicle that is standing out in the sun.
• Do not leave the device unattended when in use.
• Do not cover the fan's ventilation slots when the
device is switched on.
• Do not place any open sources of fire, like candles,
on the device.
• Both connection cables can become heated
when subjected to heavy loads.
• Due to high crossover resistances heating of the
plug in connector can result when using the cables
with a 12 V vehicle plug. Therefore when operating
with high loads use the connection cable with
the connection terminals.
Notice regarding disconnection
from mains-power
• This device's on/off switch does not completely
disconnect the device from the vehicle's power
and/or the battery. When the vehicle plug is
connected power is still supplied to the device.
To completely disconnect the device from the
vehicle power the 12 V vehicle plug must be re-
moved from the vehicle socket or the connection
terminals removed from the automobile battery.
Risk of personal injury!
• Do not operate the device if it has fallen or is
damaged. Have the device checked and repaired
if necessary by qualified technicians.

Technical data

DC Input
Voltage:
Maximum voltage:
Maximum power
consumption:
Low voltage alarm:
Low voltage shutdown: at 10 ± 0,3 V
Over voltage shutdown: at 16 ± 0,5 V
AC Output
Voltage:
Output power:
Continuous load:
Peak load:
Efficiency ( ):
Output wave form:
Overload protection:
Temperature shut off:
USB Port
Voltage:
Output current:
Fusing
Power inverter:
General data
Measurements (without vehicle plug)
(L x B x H):
Weight (without cable): 860 g approx.
Operating temperature: 5...40 °C
Operational humidity:
Subject to technical changes!
- 13 -
GB/MT
12 V
15,6 V
40 A
at 10,5 ± 0,3 V
220-240 V ~ 50 Hz
1,3 A
max. 300 W
max. 600 W/0,1 s
approx. 82 %
modified sine
>= 320 W
at 65°C ± 5°C
5 V
500 mA
40 A Car-type fuse
188 x 127 x 61 mm
0 - 80 %
(relative humidity
no condensation)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tsw 300 a1

Table of Contents