Black band
Possible cause
Corona failure
Corona failure
http://slidepdf.com/reader/full/brother-8840d-service-manual
Step
Check
1
Is the wire cleaner at its home
position?
2
Is the corona wire dirty?
Brother 8840D Service Manual
Result
No
Return the wire cleaner
to its home position.
Yes
1) Clean the corona
2) If the problem still
6-48
Ground
Remedy
contacts
(2)
wire.
(2)
appears after
cleaning, replace
the drum unit.
251/361