Fisher & Paykel OS30NPX1 Installation Manual
Fisher & Paykel OS30NPX1 Installation Manual

Fisher & Paykel OS30NPX1 Installation Manual

Combination steam oven
Hide thumbs Also See for OS30NPX1:

Advertisement

Quick Links

COMBINATION STEAM OVEN
PROFESSIONAL
OS30NPX1 models
INSTALLATION GUIDE
US CA

Advertisement

Table of Contents
loading

Summary of Contents for Fisher & Paykel OS30NPX1

  • Page 1 COMBINATION STEAM OVEN PROFESSIONAL OS30NPX1 models INSTALLATION GUIDE US CA...
  • Page 2: Safety And Warnings

    SAFETY AND WARNINGS General  WARNING! Save these instructions for the local inspectors use. Please make this information available to the person installing the appliance – doing Electric Shock Hazard so could reduce your installation costs. Failure to follow this advice may result in This oven is to be installed and connected to the electricity supply only by an authorized person.
  • Page 3: During Installation

    INSTALLATION CONSIDERATIONS COMPONENTS REQUIRED PRIOR TO INSTALLATION PARTS SUPPLIED Prior to installing your oven, ensure the following: Keep all packing materials until the unit has been inspected. Inspect the product to ensure there is no shipping damage. If any damage is detected The countertop and oven cavity are square and level, and are the required dimensions.
  • Page 4: Product Dimensions

    PRODUCT DIMENSIONS OS30 MODELS PRODUCT DIMENSIONS A Overall height 18 1/2 B Overall width 29 13/16 C Overall depth (excluding handles and dials) 22 5/16 D Height of chassis 17 9/16 PLAN ISOMETRIC E Width of chassis 25 3/8 F Depth of chassis 20 13/16 G Depth of oven frame and control panel (distance between front of chassis and front...
  • Page 5 CABINETRY DIMENSIONS (FLUSH INSTALL) Ventilation of 2" x 22 1/16" (50x560mm) or totalling 43.4in (280cm ) is required for companion products. The air vent must be located at the rear of cabinet, it can be positioned at the base, top, sides, or back of the cavity.
  • Page 6 CABINETRY DIMENSIONS (PROUD INSTALL) Ventilation of 2" x 22 1/16" (50x560mm) or totalling 43.4in (280cm ) is required for companion products. The air vent must be located at the rear of cabinet, it can be positioned at the base, top, sides, or back of the cavity.
  • Page 7: Electrical Connection

    ELECTRICAL CONNECTION SECURE THE OVEN TO THE CABINETRY Before connecting the oven to the mains power supply, check that: specifications of the electrical system match with what is detailed on this section. system has an effective ground connection compliant with current standards and laws. The ground connection is required by law.
  • Page 8 ATTACH THE LOWER TRIM TO THE OVEN Attach the lower trim to the oven after installing the oven in the cabinetry. Align the lower trim with the tabs on the base of the oven. Use the supplied screws to attach the lower trim to the tabs.
  • Page 9: Installer Checklist

    INSTALLER CHECKLIST TO BE COMPLETED BY THE INSTALLER … … Make sure the oven is level and securely fitted to the cabinetry. Turn the power to the oven on. The display should turn on.. … … Check the lower trim is correctly attached and undamaged. Have you demonstrated basic operation to the customer? …...
  • Page 10 FISHERPAYKEL.COM © Fisher & Paykel Appliances 2021. All rights reserved. The models shown in this guide may not be available in all markets and are subject to change at any time. The product specifications in this guide apply to the specific products and models described at the date of issue.

Table of Contents