Fisher & Paykel OS30NPX1 Installation Manual page 6

Combination steam oven
Hide thumbs Also See for OS30NPX1:
Table of Contents

Advertisement

B
A
E
FRONT ELEVATION
without front panels
CAVITY DIMENSIONS
A Minimum inside height of cavity
B Minimum inside width of cavity
C Minimum inside depth of cavity
D Minimum height between cabinetry front panels
E Overall width of cabinetry
F Overall height of spacer in base of cavity
G Ventilation gap
H Minimum clearance to adjacent cabinetry or other appliances
6
CABINETRY DIMENSIONS (PROUD INSTALL)
Ventilation of 2" x 22 1/16" (50x560mm)
or totalling 43.4in
2
(280cm
2
) is required
for companion products. The air vent
G
must be located at the rear of cabinet,
it can be positioned at the base, top,
sides, or back of the cavity.
D
C
SIDE ELEVATION
with front panels
H
F
H
OS30 MODELS
INCHES
MM
18 3/8
467
25 3/8
645
22 1/16
560
18 11/16
474
30
762
1/2
12
2
50
1/16
2
Additional spacer
DETAIL – PLAN VIEW
Sidewall of
appliance cabinet
Steam/Speed Oven
Min 1/16"
(2mm)
Sidewall
of adjacent
cabinet
Front panel
of adjacent
cabinet

Advertisement

Table of Contents
loading