Fisher & Paykel OS30NPX1 Installation Manual page 5

Combination steam oven
Hide thumbs Also See for OS30NPX1:
Table of Contents

Advertisement

B
A
E
FRONT ELEVATION
without front panels
CAVITY DIMENSIONS
A Minimum inside height of cavity
B Minimum inside width of cavity
C Minimum inside depth of cavity (from front of rebate)
D Minimum height between cabinetry front panels
E Overall width of cabinetry
F Minimum overall depth of cavity (incl. front panel)
G Rebate depth for flush install (incl. front panel)
H Overall height of spacer in base of cavity
I Ventilation gap
J Minimum clearance to adjacent cabinetry or other appliances
CABINETRY DIMENSIONS (FLUSH INSTALL)
Ventilation of 2" x 22 1/16" (50x560mm)
or totalling 43.4in
2
(280cm
2
) is required
for companion products. The air vent
I
must be located at the rear of cabinet,
it can be positioned at the base, top,
sides, or back of the cavity.
D
G
C
F
SIDE ELEVATION
with front panels
J
H
J
OS30 MODELS
INCHES
MM
18 11/16
474
25 3/8
645
22 1/16
560
18 11/16
474
30
762
23 5/8
600
1 9/16
39
1/2
12
2
50
1/16
2
Additional spacer
Critical rebate to
achieve flush finish
DETAIL – PLAN VIEW
Sidewall of
appliance cabinet
Steam/Speed Oven
Min 1/16"
(2mm)
G
Sidewall
of adjacent
cabinet
1 5/8"
(39mm)
Front panel
of adjacent
cabinet
5

Advertisement

Table of Contents
loading