Setting the Active Station Count

The actual number of stations being used for irrigation must be entered
to enable accurate automatic scheduleing. By default, all stations are used
in the scheduling computations.
!
Important:
If the actual number of active stations is not entered, errors and low
controller performace can result. Setting the active station count higher
than actual will add unnecessary time to the Water Window causing an
alert condition to occur. Setting the station count lower than actual will
prevent some stations from operating.
Note: The active station count entered in this step will also determine the
number of stations that can be accessed within the Programming, Review
and Copy function procedures.
Within the Setup menu, turn the Upper Line knob to view the
1.
following display:
SET ACTIVE STATIONS
10
2.
The maximum number of active station will be displayed by default.
To change the number of active stations, turn the Lower Line knob.

Selecting the Master Valve Control Option

Operation of the Master Valve (MV) control circuit can be enabled
or disabled as needed. By default the MV circuit is enabled.
W
itihin the Setup menu, turn the Upper Line knob to view the
1.
following display:
SET MASTER VALVE
Enabled
By default, the Master Valve circuit is Enabled. To disable the
2.
MV
circuit, turn the Lower Line knob to select Disabled.
10
(MAX AVAILABLE=12)