Master BLP 16 User And Maintenance Book page 15

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
ATTENTION: If the heater stops due to
en
the intervention of the room thermostat
it
(optional article), the appliance will
switch back on automatically when
de
the temperature drops below the
es
threshold set.
fr
►►8. HEAT CAPACITY
nl
REGULATION
pt
Depending on the type of heater, the
appliance heat capacity can be regulated.
da
The heat capacity can be regulated by
fi
acting on the knob positioned on the base
no
of the heater (Pic. 22) or on the pressure
regulator installed on the gas cylinder
sv
(Pic. 23), depending on the model.
pl
►►9. SWITCH-OFF FOR MANUAL
ru
MODELS (... / ...M / ...DV / ...M DV)
cs
►9.1.Close the gas cylinder (Pic. 24).
hu
►9.2.Leave the fan to cool for about 60 s,
in order to prevent internal damage due
sl
to overheating (heater internal cooling).
tr
►9.3.Take the "O/I" switch to position "O"
hr
(Pic. 25).
►9.4.Disconnect the heater from the
lt
mains electricity (Pic. 26).
lv
►9.5.Disconnect the heater from the gas
supply pipe (Pic. 27-28-29).
et
ro
►►10. SWITCH-OFF FOR
ELECTRONIC MODELS (...E /
sk
...ET)
bg
►10.1.Take the "O/I" switch to position
uk
"O" (Pic. 25). The flame goes out and
the heater performs the post-ventilation
bs
phase. Wait for the cycle to be completed
el
in order to prevent internal damage due
zh
to overheating (the phase is automatic
and can last 50 s÷5 min depending on
the internal/external temperature at the
heater).
►10.2.Close the gas cylinder (Pic. 24).
►10.3.Disconnect the heater from the
mains electricity (Pic. 26).
►10.4.Disconnect the heater from the
gas supply pipe (Pic. 27-28-29).
N.B.: Do not disconnect the heater
from the mains electricity, before the
end of the post-ventilation phase, in
order to prevent internal damage due
to over-heating.
►►11. CLEANING AND
MAINTENANCE
Have the after-sales assistance check
correct functioning of the heater at least
once a year and/or as required. The
appliance must be cleaned before it is
put away after use.
►11.1.Before
starting
maintenance, care and repairs of the
appliance,
carry
sequence [Par. 9. "SWITCH-OFF FOR
MANUAL MODELS (... / ...M / ...DV /
...M DV)" or "10. SWITCH-OFF FOR
ELECTRONIC MODELS (...E / ...ET)"].
►11.2.Cleaning only concerns the air
vent (rear side) of the heater.
►11.3.When the appliance is used
again, check the state of integrity of the
gas hose and power supply cable. If in
doubt regarding their integrity, request
the assistance of the technical after-sales
service.
►11.4.Do not carry out unauthorised
interventions.
►►12. ROOM THERMOSTAT
CONNECTION (...E / ...ET)
(optional)
Remove the plug connected to the
appliance
and
thermostat (optional) (Pic. 30).
See wiring diagram (...E / ...ET).
any
type
out
the
switch-off
connect
the
room
of