Regular inspection of other components
Regularly inspect the receiver (2) for damage or
corrosion signs. In case of damage of the receiver (2),
repairing on your own (mechanically or by welding)
EN
is prohibited. The damaged receiver (2) should be
replaced completely, by an authorized IVT Service
Centre.
Check periodically and regularly the condition of
the safety valve (11) and pressure gauge (8).
Clean properly and periodically the compressor
pump (15).
Inspection of the non-return valve (26) condition
If pressure drops in the receiver (2) at stopped
compressor and cut off compressed air consumers, you
should inspect the non-return valve (26).
1.
Pull out the plug (24), take out the spring (25) and
the non-return valve (26).
2.
Clean (or replace, if necessary) the non-return
valve (26). Clean also the seat where the non-return
valve is located.
3.
Place the non-return valve (26) and the spring (25)
on their locations and tighten the plug (24).
[F7]
Transport
Transport the machine only by the handle (6).
Moving the machine by other elements is prohibited.
Long term storage
If the machine is stored for a long time, oil should be
completely drained from the oil tank.
Do not store device unprotected outdoors or in
damp environment.
Do not lay device on its side for transportation or
storing.
NOTE: when applying to an IVT Service Center because
of problems with the machine, please make sure the oil
tank is filled with 1/3 of the oil volume.

ENVIRONMENTAL PROTECTION

Recycle raw materials instead of
disposing as waste.
Tool, accessories and packaging should be sorted for
environment-friendly recycling.
The plastic components are labeled for categorized
recycling. These instructions are printed on recycled
paper manufactured without chlorine.