X7DWE User's Manual
Hardware Monitor Logic
Highlight this and hit <Enter> to see monitor data for the following items:
CPU1 Temperature/CPU2 Temperature/System Temperature
Fan1-Fan6 Speeds:
If the feature of Auto Fan Control is enabled, the BIOS will automatically display
the status of the fans indicated in this item.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When
the CPU on-die temperature increases, the fan speed will also increase, and vice
versa. Select Workstation if your system is used as a Workstation. Select Server
if your system is used as a Server. Select 3-pin if your chassis uses 3-pin fans.
Select 4-pin if your chassis uses 4-pin fans. Select "Disable" to disable the fan
speed control function and allow the onboard fans to constantly run at the full
speed (12V). The Options are: 1. Full Speed @12V, 2. Optimized Server w/3-pin,
3. Optimized Workstation w/3-pin, 4. Optimized Server w/4-pin, and 5. Optimized
Workstation w/4-pin.
Voltage Monitoring
The following items will be monitored and displayed:
VcoreA/VcoreB, +12V/-12V, +5Vsb/+5VDD, +3.3V, P1V5/P_VTT/Vbat
Note: In the Windows OS environment, the Supero Doctor III settings take
precedence over the BIOS settings. When fi rst installed, Supero Doctor III
adopts the temperature threshold settings previously set in the BIOS. Any
subsequent changes to these thresholds must be made within Supero Doc-
tor, since the SD III settings override the BIOS settings. For the Windows
OS to adopt the BIOS temperature threshold settings, please change the
SDIII settings to be the same as those set in the BIOS.