Lan/Rs-232 Command Reference; Lan Interface; Rs-232 Interface; Command Format - Roland VR-6HD Manual

Direct streaming av mixer
Hide thumbs Also See for VR-6HD:
Table of Contents

Advertisement

LAN/RS-232 Command Reference

The VR-6HD support two types of remote-interface communication: LAN and RS-232.
Using the LAN CONTROL port or RS-232 connector to send specific commands to the VR-6HD from a controlling device lets you operate the VR-6HD remotely.

LAN Interface

This uses the LAN CONTROL port on the VR-6HD.
You use Telnet to operate the VR-6HD remotely over a LAN (TCP/IP
protocol).
Communication standards
Port
LAN CONTROL jack
TCP port number
8023
Specifying the VR-6HD's Network Settings
[MENU] button Ó "NETWORK" Ó select the menu item
1 .
shown below, and press the [VALUE] knob.
Menu item
Explanation
Selects how settings are made for the IP
address, subnet mask, and default gateway.
USING DHCP:
The IP address and other information needed
CONFIGURE
for connecting to the network is obtained
automatically from the DHCP server of the LAN.
MANUALLY:
The IP address, subnet mask, and default
gateway are specified manually.
IP ADDRESS
Shows the IP address. (*1)
SUBNET MASK
Shows the subnet mask. (*1)
DEFAULT GATEWAY
Shows the default gateway. (*1)
(*1) When "CONFIGURE" is set to "MANUALLY", set these respectively
according to the network.
2 .
Use the [VALUE] knob to change the value of the setting.
3 .
Use the [VALUE] knob to select "NETWORK PASSWORD",
and press the [VALUE] knob.
4 .
Set a network password (four characters).
Input the password that's set here when connecting a computer or other
device on the same network to access the VR-6HD.
5 .
Press the [MENU] button to close the menu.

RS-232 Interface

RS-232 connector pin layout
1
2
3
4
6
7
8
9
DB-9 type (male)
Communication standards
Communication method
Communication speed
Parity
Data length
Stop bit
Code set
Cable wiring diagram
Use an RS-232 crossover cable to connect the VR-6HD and the
controller (an RS-232-compatible computer or other device).
VR-6HD
N.C.: 1
RXD: 2
TXD: 3
DTR: 4
GND: 5
DSR: 6
RTS: 7
CTS: 8
N.C.: 9
(Crossover connection)
* The connections between 4 and 6 and between 7 and 8 are inside the
VR-6HD.

Command Format

Commands are formatted using the configuration shown below.
Commands are all in ASCII code.
* Commands are common to the LAN and the RS-232 interface.
stx
Command code
ASCII code "02H" is a control code indicating the start of
stx
a command. "H" indicates that it is a hexadecimal value.
This specifies the command type (three single-byte
Command code
alphanumeric characters).
This is appended to a command that requires one or
more parameter. The command and the parameter
Parameter
portion are separated by a " : " (colon). When there are
multiple parameters, they are each separated by " , "
(comma) characters.
This is the code that this unit recognizes as the end of
;
a command.
* The codes of stx (02H), ack (06H), xon (11H), and xoff (13H) are the control
codes.
32
Pin assignments
Pin No.
Signal
1
N.C.
5
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
N.C.
Synchronous (asynchronous), full-duplex
9,600/38,400/115,200 bps
none
8 bits
1 bit
ASCII
Control device
1:
2: RXD
3: TXD
4:
5: GND
6:
7:
8:
9:
:
Parameter
,
Parameter
;

Advertisement

Table of Contents
loading

Table of Contents