Bosch Rexroth II 3G Manual page 28

Directional seat valves, direct operated, with solenoid actuation
Table of Contents

Advertisement

28/48
Assembly
Bosch Rexroth AG, M-.SED 6...XN..., RE 22049-XN-B/05.17
Exchanging P and T may cause damage at the valve in case of pressurization.
7.
Place the valve on the contact surface. If applicable, assemble the Plus-1 plate
between valve and connection surface.
For reasons of stability, exclusively use the valve mounting screws specified in
chapter 7.6 "Required accessories"!
Always fasten the valve with all 4 valve mounting screws as otherwise, leak-
tightness is not guaranteed.
8.
When using the subplates mentioned in 7.6 "Required accessories" or in case
of assembly on comparable cast iron installation surfaces, tighten all four valve
mounting screws using a torque power screwdriver (tolerance ≤ 10 %) and
a tightening torque of 7 Nm (5.2 ft-lbs) ± 10 %. This tightening torque refers to
the maximum admissible operating pressure.
If the valve is to be used at a reduced maximum pressure and in this connection
is to be mounted on connection surfaces of a different material, it might be
necessary to use a lower tightening torque in order to exclude any damage.
7.7.2 Hydraulically connecting the valve
Damage to the valve!
If you install hydraulic lines and hoses under pressure, they are exposed to
additional mechanical forces during operation, which reduce the life cycle of the
valve and the complete machine or system.
Assemble lines and hoses without stress.
1.
Depressurize the relevant system part.
2.
Establish all connections; in this connection, observe the operating instructions
of the system.
3.
Make sure that pipes and/or hoses are connected to all ports and/or that the
ports are closed with plug screws.
4.
Carry out a special check to make sure that the cap nuts and flanges are correctly
tightened at the pipe fittings and flanges.
Mark all checked fittings, e.g. using a permanent marker.
5.
Make sure that all pipes and hose lines and every combination of connection
pieces, couplings or connection points with hoses or pipes are checked for their
operational safety by a person with appropriate knowledge and experience.
CAUTIOn