Bosch Rexroth II 3G Manual page 19

Directional seat valves, direct operated, with solenoid actuation
Table of Contents

Advertisement

Zones, device groups
and categories
Device group
Category
according to
according to
2014/34/EU
2014/34/EU
I
M1
I
M2
II
1G
II
2G
II
3G
II
1D
II
2D
II
3D
5.1.2 Explosion protection marking
According to EU directive 1999/92/EC, the user/machine end-user has to classify
explosive areas into zones. In the following table, the corresponding zones for device
groups and categories are shown.
The valve may only be used in the areas and zones which correspond to the device
group and category. During use, also observe the other information on the explosion
protection in "Data sheet 22049-XN".
Table 7: Device groups and categories
Area of application, properties (excerpt from the directives)
Areas susceptible to firedamp (=device group I), i.e.: underground mines and their
pitheads. If there is an explosive atmosphere, the operation can continue.
Very high level of safety.
Areas susceptible to firedamp (=device group I), i.e.: underground mines and their
pitheads. If there is an explosive atmosphere, it must be possible to switch off
the device.
High level of safety.
Explosive areas in which explosive gasses, mists or vapors (=device group II)
occur permanently or for a long time or frequently.
Corresponds to zone 0 according to directive 1999/92/EC.
Very high level of safety.
Explosive areas in which explosive gasses, mists or vapors (=device group II)
occur sometimes.
Corresponds to zone 1according to directive 1999/92/EC.
High level of safety.
Explosive areas in which explosive gasses, mists or vapors (=device group II) do not
normally occur or only rarely or for a short time.
Corresponds to zone 2 according to directive 1999/92/EC.
Standard level of safety.
Explosive areas in which explosive dust/air mixtures (=device group II) occur
permanently or for a long time or frequently.
Corresponds to zone 20 according to directive 1999/92/EC.
Very high level of safety.
Explosive areas in which explosive dust/air mixtures (=device group II) occur
sometimes.
Corresponds to zone 21 according to directive 1999/92/EC.
High level of safety.
Explosive areas in which an explosive atmosphere due to blown up dust
(=device group II) does not normally occur or only rarely or for a short time.
Corresponds to zone 22 according to directive 1999/92/EC.
Standard level of safety.
Product information
RE 22049-XN-B/05.17, M-.SED 6...XN..., Bosch Rexroth AG
19/48
Usable in zone
according to
1999/92/EC
-
-
0, 1, 2
1, 2
2
20, 21, 22
21, 22
22