Technical Specifications Ac Power Supply (Ac); Technical Specifications Of Direct Voltage Power Supply (Dc) - Siemens SIMATIC IPC677E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC677E:
Table of Contents

Advertisement

Technical specifications
8.3 Current/power consumption and power supply
8.3.2

Technical specifications AC power supply (AC)

Technical specifications
Note
The power supply contains an active PFC (Power Factor Correction) circuit to conform to the
EMC guidelines.
Uninterruptible AC power systems (UPS) must supply a sinusoidal output voltage in the
normal and buffered mode when used with SIMATIC PCs with an active PFC.
UPS characteristics are described and classified in the standards EN 50091-3 and
IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are
identified with the classification "VFI-SS-...." or "VI-SS-....".
Power supply characteristics
Input data
Voltage
Frequency
Continuous current
Starting current (load-
independent)
Active power
Apparent power
Output data
Voltages
Secondary power output
8.3.3

Technical specifications of direct voltage power supply (DC)

Technical specifications
Power supply characteristics
Input data
Voltage
Continuous current
Starting current (load-
independent)
Active power
Output data
Voltages
Secondary power output
114
AC power supply
Nominal 100 - 240 V AC (-15% / +10%), wide range
Nominal 50 Hz to 60 Hz (min. 47 Hz to max. 63 Hz), sinusoidal
to 50 A for 1 ms
+12 V / 12.5 A
Max. 150 W
DC power supply
Nominal 24 V DC (-20% / +20%), SELV, isolated
Max. 8 A
up to 14 A for 20 ms
+12 V / 12.5 A
Max. 150 W
Operating Instructions, 04/2019, A5E45117996-AA
Max. 2.5 A
176 W
190 VA
176 W