Congratulations on purchasing the latest technology temperature controlled Rinnai gas continuous flow water
heater system.
The Rinnai gas continuous flow water heater products NEVER RUN OUT of hot water. Whilst electricity,
water and gas supplies are connected, hot water is available whenever hot water taps are open.
Built into the main micro-processor is the facility to LIMIT THE MAXIMUM TEMPERATURE of the hot water
supplied. The water temperature may be limited to various values. This is particularly useful when the hot
water unit is installed where young children or the infirm may be using the hot water.
The Rinnai gas continuous flow water heater products are Fan-Assisted (power flued) appliances. This
makes them COMPACT, saving both floor and wall space.
The temperature of hot water is CONSTANTLY MONITORED by a BUILT-IN SENSOR. If the temperature
of the hot water rises to more than 3°C above the selected temperature the burner is turned OFF and only
turned ON again when the temperature falls below the selected temperature.
The burner lights automatically when the hot water tap is opened, and goes out when the tap is closed.
IGNITION IS ELECTRONIC, so there is no pilot light. When the hot water tap is off, no gas is used.
'Deluxe' or 'Universal' Water Controllers are available as an optional extra. Depending on the models chosen,
these offer the following features:
-
Bath fill function (Deluxe Bathroom Control Only).
-
Voice Prompting (Deluxe Control Only).
-
Clock (Deluxe Control Only).
-
Up to three water controllers can be fitted. See page 9 for details.

For further information regarding Wireless and Deluxe water controllers please contact Rinnai or visit
www.rinnai.com.au.
The "Smartstart®" system when fitted can pre-heat the water in the pipe-work between the water heater and
the hot water outlets. This results in water savings and reduces waiting time for heated water at the outlets.
Operating NOISE LEVEL IS VERY LOW.
ERROR MESSAGES ARE DISPLAYED on the Water Controllers and Status Monitor, assisting with
service.
A high altitude setting is built into the programming, and can be enabled, for those installation applications
sited from 610 to 2000 metres above sea level such as Alpine regions.