Rinnai HD28E Operation & Installation Manual

Rinnai HD28E Operation & Installation Manual

Commercial manifold pack

Advertisement

Commercial Manifold Pack
Operation & Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai HD28E

  • Page 1 Commercial Manifold Pack Operation & Installation Manual...
  • Page 2 Congratulations on the purchase of your Rinnai Manifold Pack System. We trust you will have many years of comfort and enjoyment from your appliances. This manual applies to Manifold Pack Systems utilising HD model continuous flow water heaters. BEFORE USING THIS APPLIANCE SYSTEM...
  • Page 3: Table Of Contents

    Ring Main Pump ������������������������������������������������������������������������������������������������������������������������������������������� 18 Gas Supply ��������������������������������������������������������������������������������������������������������������������������������������������������� 18 Electrical Supply ������������������������������������������������������������������������������������������������������������������������������������������� 18 Filling Instructions ��������������������������������������������������������������������������������������������������������������������������������������������� 18 Rinnai Manifold Electronic Control System - MECS and Cascade ������������������������������������������������������������������ 19 FAULT FINDING Manifold Pack Preventative Maintenance �������������������������������������������������������������������������������������������������������� 20 Ring Main Pump ����������������������������������������������������������������������������������������������������������������������������������������������� 21 Service �������������������������������������������������������������������������������������������������������������������������������������������������������������...
  • Page 4: Warnings & Important Information

    DO NOT activate pump unless cylinder is full of water. Not suitable as a pool or spa heater. All Rinnai Manifold Pack (MP) systems and components are Watermark Certified by SAI Global as applicable. All dimensions referred to in these instructions are in millimetres, unless otherwise specified.
  • Page 5: Notice To Victorian Consumers

    Rinnai. Take care of not to touch the power plugs with wet hands. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Page 6: Hydrogen Gas

    Your local plumbing authority may already require that these be fitted. Contact your installer or local plumbing authority if in doubt. Never…. Leave a toddler in the care of another child. They may not understand the need to have the water temperature set at a safe level. Rinnai Commercial Manifold Pack OIM...
  • Page 7: Save A Service Call

    If this is not the case, the temperature may need to be increased. Contact your installer or Rinnai to discuss adjusting the temperature. No water from the hot tap? Restriction in the hot tap or failure of the cold water supply to the heater.
  • Page 8: Installation

    Gas booster flue terminals must be located in accordance with AS/NZS 5601 Fig 6.2 “Location of balanced flue terminals”. Rinnai HD units are fan assisted appliances and thus have lower clearances than a natural draft appliance of the same MJ rating.
  • Page 9: Horizontal Obstructions

    AS/NZS 5601-2010 ‘Gas Installations’ stipulates a minimum horizontal clearance of 500mm between a building structure and obstruction facing the terminal. For Rinnai External continuous flow water heaters such a building structure must ‘obstruct’ the full front cover height of the appliance, or extend vertically above and below the front cover.
  • Page 10: Horizontal Flue Terminal Clearances (Extract From As/Nzs 5601)

    For minimum clearances not addressed above acceptance should be obtained from the Technical Regulator. Minimum clearances d and e also apply to any combustion air intake openings of appliances. FIGURE 6.2 (in-part) LOCATION OF FLUE TERMINALS OF BALANCED FLUE, ROOM-SEALED, FAN-ASSISTED OR OUTDOOR APPLIANCES Rinnai Commercial Manifold Pack OIM...
  • Page 11: Co-Axial Flueing For Internal Models

    This system is certified and suitable for use with Rinnai internal commercial continuous flow water heaters. The Rinnai flueing system must be installed in accordance with the instructions supplied with the flue terminal. Non Rinnai flueing systems MUST NOT be used.
  • Page 12: Multiple Flue Terminals

    MULTIPLE FLUE TERMINALS Dimension 'H' in AS/NZS 5601 Figure 6.2 does not apply when multiple Rinnai external water heaters of the same model are installed on the same vertical face with flue terminals at the same height (i.e. side by side). Under these...
  • Page 13: Installation Options

    MULTIPLE RINNAI CONTINUOUS RINNAI COMMON PLANT ROOM VENTILATION FLOW WATER HEATERS FLUE INSERT TERMINAL AND COMBUSTION AIR For more information on the flue system, please refer to the Rinnai Commercial Common Flue System Operation & Installation Manual. Rinnai Commercial Manifold Pack OIM...
  • Page 14 When turning over to correctly orient heaters beware that system is top heavy. Assembly: A Rinnai Manifold Pack is supplied in modules of either 2 or 3 HD continuous flow units plumbed in parallel and mounted on a dedicated and lightweight frame. Standard systems can be installed together in any order by coupling the barrel unions supplied with the copper header pipes.
  • Page 15 Cascade System. MECS and Cascade are sophisticated electronic control systems that are supplied pre-wired except for the module connections. Refer to the separate installation booklet supplied for full details on how to connect each heater control. Rinnai Commercial Manifold Pack OIM...
  • Page 16: Manifold Pack With No Reticulation System

    Not all heaters may fire up as its flow rate dependent. To verify all heaters are operational either open some outlets or, if this is not practical, close the cold water valve underneath the currently operating heaters to restrict the flow. Other heaters should then fire up. • Clean all filters on completion Rinnai Commercial Manifold Pack OIM...
  • Page 17: Specifications

    SPECIFICATIONS TYPICAL RINNAI MANIFOLD PACK INSTALLATION Appliance Dimensions Model Weight HD200 Manifold Packs MP2 28 60 Kg MP3 28 1125 90 Kg MP4 28 1500 120 Kg 1500 MP5 28 1875 150 Kg MP6 28 2250 180 Kg HD210 Manifold Packs...
  • Page 18: Installation Handover Manual

    Ring Main Pump • A secondary or building return pump may be installed in conjunction with the Rinnai Manifold Pack hot water system. Pump should be sized for minimal temperature loss around the ringmain. Pump must have a check valve on the discharge.
  • Page 19: Rinnai Manifold Electronic Control System - Mecs And Cascade

    Rinnai Heavy Duty Units require a minimum of either 1.5 l/min or 2.4l/min (depending on which water heater is used) per heater before they can operate. If this is not achieved they will not fire. When there is an expected scenario that results in a lower flow per heater a staging system is required.
  • Page 20: Fault Finding

    MANIFOLD PACK PREVENTATIVE MAINTENANCE Your Rinnai Continuous Flow water heaters have self diagnostic capability. If a fault occurs, an Error Code will flash on the status monitor or inbuilt controller. If you have Water Controllers, this assists with diagnosing the fault and may enable you to overcome a problem without a service call.
  • Page 21: Ring Main Pump

    This may be indicated by Fault 10. Contact Rinnai Service. • Internal heaters may operate for a short period of time and then stop. This can be caused by Rinnai Co-axial flueing not being pushed together properly and exhaust gases are re-entering the inlet air. Check flue connections.
  • Page 22: Commercial Hot Water System Commissioning Check-List

    Socket Outlet Installation – Satisfactory? Yes / No / NA MECs/Cascade staging system wiring completed? YES / No / NA Parameters Gas Pressure (@1.13-2.75kPa–NG) / @2.75kPa-LPG) • Static • Running Inlet Water Pressure (kPa) Permanent Power Supply (V/Phase/Hz/A) 240/1/50 Rinnai Commercial Manifold Pack OIM...
  • Page 23 5.0m in any direction from any air duct intake. • Warranty: https://www.rinnai.com.au/wp-content/uploads/2018/02/15401043-V6-Commercial-Warranty-Booklet.pdf • Installation of system to comply within Rinnai installation guidelines and relevant codes • Drainage: Provide appropriately designed drainage system in compliance to applicable building codes and regulations to prevent property and equipment damage. Customer Representative...
  • Page 24: Contacts

    *Cost of a local call higher from mobile or public phones. For further information visit www.rinnai.com.au or email enquiry@rinnai.com.au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line.