Direct vent tankless water heater, temperature controllers (194 pages)
Summary of Contents for Rinnai HOTFLO
Page 1
® ‘HOTFLO’ Operation / Installation Manual Mains Pressure Vitreous Enamel Electric Storage Water Heater Installation and Service must be performed by an authorised person. THIS APPLIANCE IS NOT SUITABLE FOR USE AS A POOL OR SPA HEATER. This appliance shall be installed in accordance with:...
REGULATORY INFORMATION Your Rinnai Hotflo Mains Pressure Vitreous Enamel Storage Electric Water Heater has been certified by relevant plumbing and electrical authorities and the details are shown on data plate. This appliance must be installed correctly by an authorised person and must conform to location regulations.
Connection to a low pressure gravity or tank water supply.............. 12 HOT WATER STORAGE AND DELIVERY TEMPERATURES............12 Storage Temperature........................12 Sanitary Fixtures Delivery Temperature ..................12 Water Pipes ............................. 12 Electrical Supply ..........................13 Valves and fittings..........................13 Rinnai Australia - ii - HOTFLO Electric Storage Tanks Operating/Installation Manual...
Page 4
Definition of Commercial Use ......................18 WARRANTY ......................18 WARRANTY CONDITIONS......................19 Table 3 - Water chemistry and impurity limits for all water heating systems ........19 WARRANTY EXCLUSIONS ......................19 CONTACT INFORMATION ..................21 Rinnai Australia - iii - HOTFLO Electric Storage Tanks Operating/Installation Manual...
Do make sure that the tap is authority if in doubt. turned off tightly. • Do install a child proof tap cover OR • Do install a child resistant tap. Rinnai Australia - 4 - HOTFLO Electric Storage Tanks Operating/Installation Manual...
The Off-Peak supply allows heating only for set periods and a volume of water sufficient for daily usage is heated during the set period and stored. The Off-Peak supply is usually cheaper. Electricity supply types and tariffs vary according to the local electricity authority. Rinnai Australia - 5 - HOTFLO Electric Storage Tanks Operating/Installation Manual...
Expansion Control Valve (ECV) if fitted Operate the easing lever on the expansion control valve once every six months. It is very important you raise and lower the lever gently. Rinnai Australia - 6 - HOTFLO Electric Storage Tanks Operating/Installation Manual...
SERVICING AND REPAIR Our Servicing network personnel are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance needs service, ring one of the service contact numbers on the back of this booklet. The pressure and temperature relief valve and expansion control valve must be checked for performance or replaced by an authorised person at intervals not exceeding 5 years or more frequently in areas where the water is classified as scaling water (see ‘Water Quality’).
The system should be checked and serviced by an authorised person at least every 5 years. The P&TR valve must be replaced at intervals not exceeding five (5) years. Rinnai has a service and spare parts network with personnel who are trained and equipped to give the best service on Rinnai appliances.
700 kPa Valves with pressure ratings other than specified are unsuitable & must not be used. NOTE Figure 2 - Hot Water Plumbing System Example - No Temperature Limiting Device Rinnai Australia - 9 - HOTFLO Electric Storage Tanks Operating/Installation Manual...
Valves with pressure ratings other than specified are unsuitable & must not be used. NOTE Figure 4 - Hot Water Plumbing Water Heater system Example - with Flow & Return Pipe Work Rinnai Australia - 10 - HOTFLO Electric Storage Tanks Operating/Installation Manual...
Figure 5 - Hot Water Plumbing System Example with Flow and Return Pipe Work and TLD WATER HEATER LOCATION All Rinnai mains pressure electric storage hot water systems have an ingress protection rating of IPX4 making them suitable for internal or external installation.
12mm are used. If drilling is required take extreme care not to penetrate the inner cylinder. Damage to the inner cylinder is not covered under warranty. Rinnai Australia - 12 - HOTFLO Electric Storage Tanks Operating/Installation Manual...
(refer to Specifications - Table 1 for electrical load details). A power cord is available for replacement. Please contact Rinnai Customer Care for part number. A water heater fitted with a power cord & plug must be plugged into a switched, AC 240V AC, 50 Hz mains power outlet rated at 10 Amps.
The thermostat is adjustable from 60°C to 75°C. Turning the adjustment knob anticlockwise decreases the temperature setting and turning it clockwise increases the temperature setting. Rinnai advice that the thermostat be set at 65° C, this temperature is sufficient for most users. Ensure the power supply is switched OFF before removing the access cover to the element &...
• Operate the P&TR valve again. This allows air into the water heater and will result in water draining through the hose. Rinnai Australia - 15 - HOTFLO Electric Storage Tanks Operating/Installation Manual...
50 - Rated Capacity of the tank Legend S - Single heating element 24 - First two digits of the Heating element rating eg. 24 = 2400 Watts - Specifications Table 1 Rinnai Australia - 17 - HOTFLO Electric Storage Tanks Operating/Installation Manual...
Given installation and application is in accordance with the manufacturers specifications and instructions, Rinnai water heaters and components are warranted by Rinnai for the cost of labour and components in the event of defects arising from faulty materials and/or workmanship in accordance with the Terms in Table 2 and Warranty Conditions and Exclusions stated in this document.
3. All Rinnai water heaters must be operated and maintained in accordance with manufacturers operating instructions. 4. The warranty applies only to the components supplied by Rinnai. It does not apply to components supplied by others, such as pressure limiting valves, isolating valves, non return valves, electrical switches, pipework, electrical cables and fuses.
Page 21
______________________________________ Purchase Date :________________________ Installers License No::____________________ Your Installer :________________________ Phone :____________________________ Address :______________________________________________________________________ Installation Date :_______________________ Cert' of Compliance No :__________________ Model No :_____________________________ Serial No : __________________________ Rinnai Australia - 20 - HOTFLO Electric Storage Tanks Operating/Installation Manual...
Fax: (03) 9271 6622 Hot Water Service Line Tel: 1800 000 340 Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance U283-931 requires service, please call our Hot Water Service Line.