Download Print this page

JVC GZ-MS100AC Service Manual page 14

Memory camcorder

Advertisement

Removing HINGE UNIT ASSY
(1) Remove the screw (5), and remove the HINGE COV-
ER(U).
(2) Remove the HINGE COVER(L).
(3) Remove the MAGNET.
NOTE15n:
During the procedure, be careful in handling the FPC.
During the procedure, be careful in handling the MAG-
NET.
When attaching, set the N pole outside as shown in
the figure. Be careful when removing as there is no
marking.
NOTE15p:
During the procedure, be careful in handling the FPC.
NOTE15q:
The FPC, with its connection to the MONITOR
BOARD ASSY facing inward, is rolled around the axis
(shaft) of the HINGE UNIT ASSY rotation 2.5 rounds
(2.5times).