Operations Overview; Starting - Atlas Copco PTS 800 T3 Cud Instruction Manual

Portable compressors
Table of Contents

Advertisement

Measuring view
MEASUREMENTS
LOADED
ECU ENGINE RPM
PAR -> ECU RPM SETPONIT
AIR DISCHARGE PRESSURE
REGULATOR PRESSURE INPUT
LOW PRESSURE ELEMENT TEMPERATURE
MEDIUM PRESSURE ELEMENT TEMPERATURE
HIGH PRESSURE ELEMENT TEMPERATURE
40%
1286h
1300RPM
Use the Up and Down navigation buttons to scroll
through the full list of measurements.

5.2.4 Operations overview

It is possible to control the compressor:
– locally, directly operating the Pc4003™ control
module (Local Operation Mode),
– automatically, by setting triggers based on
pressure sensor data in the customer's installation
(Automatic Operation Mode), or
– by using software running on a PC (PC Operation
Mode).

5.2.5 Starting

1. Switch on the battery switch.
2. Switch on the machine by switching the Pc4003™
Power Switch to the ON position.
While the machine gets powered up, the controller
will
perform
INITIALIZING SEQUENCE.
During the entire INITIALIZING SEQUENCE,
which takes about 2 seconds) the following view
is shown on the PC display:
10.3 bar
This view shows the controller version (e.g.
'Pc4003') and the application software version
(e.g. 'v1.00.0').
a
self-test
and
enter
the
- 46 -
Except for a controller power down,
nothing
can
interrupt
INITIALIZING SEQUENCE.
During
the
INITIALIZING
SEQUENCE, all buttons / inputs /
outputs / alarms are inactive.
When initialization of the controller is finished,
the INITIALIZING SEQUENCE is ended.
The display shows the Main View.
MAIN VIEW
PREPARING FOR START
0.0
bar
40%
1286h
--RPM
0.0 bar
The machine is now ready to be started and is
waiting for a start command.
the
SET
9.0
bar

Hide quick links: