4
BLACK/YELLOW
Locate the vehicle's second starter (crank) wire at the ignition switch. (if equipped)
Verification: This wire registers voltage only in the start (crank) position of
the ignition switch.
Connect the BLACK/YELLOW wire as shown in the diagram below. Use an SPDT
relay (not supplied).

2 Pin Door Lock Harness

1
BLUE
2
GREEN
The door lock / unlock outputs are designed to control several different types of
systems which may require additional parts. Please review the wire and location
chart to see which type of door lock system is in your vehicle. The most common
types are shown in the following diagrams.
2010 Audiovox Electronics Corporation. All rights reserved.
F us ed +12 Volt
B attery S ource
J ump To P UR P LE
S tarter O utput
86
W ire From T he
C ontrol Module
To Vehicle's 2nd
PULSE DURING CRANK ( - )
87
B LAC K /Y E LLOW P uls e
87a
During C rank W ire
85
30
S tarter W ire
UNLOCK ( - )
LOCK ( - )