10-5. Electrical works
Model
Power source
Maximum running current
Circuit breaker rating
Power supply cable
Connecting cable
10-5-1. Wiring Connection
<Indoor unit>
Wiring of the connecting cable can be carried
out without removing the front panel.
1. Remove the air inlet grille.
(Please see details on page 82)
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local
cords) into the pipe hole on the wall.
4. Take out the connecting cable through the cable slot
on the rear panel so that it protrudes about 20 cm
from the front.
5. Insert the connecting cable fully into the terminal
block and secure it tightly with screws.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover and air inlet grille on the
indoor unit.
9. Install the air inlet grille
(Please see details on page 82)
Screw
Terminal cover
Fig. 10-5-1
RAS-25S4KVDG-ND
50 Hz, 220 – 240 V Single phase
13.00 A
20 A
H07RN-F or 60245 IEC66 (2.5 mm
Front panel
Cord clamp
Screw
RAS-35S4KVDG-ND
<Outdoor unit>
1. Remove the valve cover, the electric parts cover
and the cord clamp from the outdoor unit.
2. Connect the connecting cable to the terminal as
identified by the matching numbers on the
terminal block of indoor and outdoor unit.
3. Insert the power cord and the connecting cable
carefully into the terminal block and secure it tightly
with screws.
4. Use vinyl tape, etc. to insulate the cords which are
not going to be used. Locate them so that they do
not touch any electrical or metal parts.
5. Secure the power cord and the connecting cable
with the cord clamp.
6. Attach the electric parts cover and the valve cover
on the outdoor unit.
- 88 -
14.00 A
20 A
or more)
2
Terminals block
Fig. 10-5-2
Valve cover

Advertisement