10-2. Installation
10-2-1. Optional installation parts
Part
code
Refrigerant piping
Liquid side : Ø6.35 mm
A
Gas side
: Ø9.52 mm
Pipe insulating material
B
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
C
<Fixing bolt arrangement of outdoor unit>
100
·
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
Use ∅ 8 mm or ∅ 10 mm anchor bolts and nuts.
·
· If it is necessary to drain the defrost water, attach drain nipple
the bottom plate of the outdoor unit before installing it.
Parts name
600
108
Drain outlet
Fig. 10-2-1
- 74 -
Q'ty
One
each
1
One
each
99
70
* Drain nipple and
cap water proof are
packed in outdoor
unit.
and cap waterproof
11
to
12