Key Features/Speci Cations/System Requirements - Curtis G4 TPX Series User Manual

1.5 gallon coffee brewing system
Table of Contents

Advertisement

KEY FEATURES/SPECIFICATIONS/SYSTEM REQUIREMENTS
Key Features
Generation Four (G4) Digital Control Module – provides precise control over all aspects of brewing: time,
temperature, volume plus specialty coffee needs from pre-infusion to pulse-brewing to water bypass. Large,
4.3" touch screen with icon-driven interface, streamlines operation. On-screen instructions provide fast,
intuitive training; reduces service calls.
Built-in Self Diagnostic System – Includes real-time feedback of the brewing process and energy saving mode.
Stainless steel ThermoPro
Pre-Set Global Recipes at the Touch of a Single Button – No complex equipment required.
Centrally located hot water spout for instant hot beverages and other hot water needs.
Industry's most effective mineral tolerant design.
Speci cations (Selected Models)
Electrical Supply Requirements
MODEL #
DESCRIPTION
G4TPX2S31Ax
Single brewer
G4TPX2S34Ax
Single brewer
G4TPX2S63Ax
Single brewer, dual voltage
G4TPX2T10Ax
Twin brewer
G4TPX2T30Ax
Twin brewer
G4TPX2T38Ax
Twin Brewer
G4TPX2T39Ax
Twin Brewer
Dimensions
MODEL #
HEIGHT
G4TPX2S31Ax
36.48"
G4TPX2S34Ax
[92.7 cm]
G4TPX2S63Ax
G4TPX2T10Ax
G4TPX2T30Ax
36.48"
[92.7 cm]
G4TPX2T38Ax
G4TPX2T39Ax
Following are the factory default settings for the ThermoPro brewer:
Brew Temperature = 200°F (92°F)
Water Bypass = On LARGE and MEDIUM brew only
G4TPX2, KEY FEATURES/SPECS/SYSTEM REQUIREMENTS
®
vacuum-sealed servers keep coffee fresh, hot and avorful.
PHASE
VOLTS
1 PH
220-240V
1 PH
220-240V
1 PH
120/220 V
1 PH
220 V
1 PH
230 V
3 PH
380-415V
3 PH
380-415V
WIDTH
DEPTH
SHIP WEIGHT
11.00"
19.72"
53.0 lb.
[27.9 cm]
[50.1 cm]
[24.0 kg]
20.00"
20.62"
75.0 lb.
[50.8 cm]
[52.4 cm]
[34.0 kg]
AMPS
HEATING CONFIG
WIRE
2W + G
11.6-12.7 A
1 x 2500 W
(1/N/PE)
2W + G
13.2-14.4 A
2 x 1700 W
(1/N/PE)
15.0/12.7 A
2 x 1600 W
2W/3W + G
23.0/34.5 A
3 x 2500 W
3W + G
24.2 A
2 x 2500 W
2W + G
4W + G
11.5-12.6 A
3 x 2500 W
(3P/N/PE)
3W + G
11.5-12.6 A
3 x 2500 W
(3P/PE)
Water Supply Requirements
SHIP CUBE
WATER CONNECTOR
9.70 cu. ft.
3/8" are
3
[0.27 m
]
14.08 cu. ft.
3/8" are
3
[0.40 m
]
Brew Volume = Large-Medium-Small
Energy Save Mode = Off
FS99
WATTS
HERTZ
CAPACITY
10.0 gal./hr.
2550-3050 W
50/60 Hz
[37.9 L/hr.]
10.0 gal./hr.
2900-3450 W
50/60 Hz
[37.9 L/hr.]
4.5/12.0 gal./hr.
1800/2800 W
50/60 Hz
[17.0/45.4 L/hr.]
15.0/21.0 gal./hr.
5100/7600 W
50/60 Hz
[56.8/79.5 L/hr.]
21.0 gal./hr.
5574 W
50/60 Hz
[79.5 L/hr.]
21.0 gal.hr.
7566-9025 W
50/60 Hz
[79.5 L/hr.]
21.0 gal./hr.
7566-9025 W
50/60 Hz
[79.5 L/hr.]
WATER PRESSURE
MIN. FLOW RATE
20 - 90 psi
1.0 gpm
[138 - 620 kPa]
[3.8 Lpm]
20 - 90 psi
2.0 gpm
[138 - 620 kPa]
[7.6 Lpm]
071421F