Fifth Edition • Fourth Printing
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power
lines and apparatus in accordance with applicable
governmental regulations and the following chart.
Line Voltage
0 to 50KV
50KV to 200KV
200KV to 350KV
350KV to 500KV
500KV to 750KV
750KV to 1000KV
Allow for platform movement, electrical line sway
or sag and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Part No. 114423
Occupants, equipment and materials must not
exceed the maximum platform capacity or the
maximum capacity of the platform extension.
Maximum Capacity
Model
GS-1530
GS-1930
GS-2032
GS-2632
GS-3232
GS-2046
GS-2646
Required Clearance
GS-3246 318 kg
3.05 m
4.60 m
6.10 m
7.62 m
10.67 m
13.72 m
GS-30 • GS-32 • GS-46
Tip-over Hazards
Platform extended
Platform
Platform Extension Maximum
retracted
only
272 kg
159 kg
227 kg
113 kg
363 kg
249 kg
227 kg
113 kg
227 kg
113 kg
544 kg
431 kg
454 kg
340 kg
204 kg
Platform retracted
Operator's Manual

Work Area Safety

only
occupants
113 kg
113 kg
113 kg
113 kg
113 kg
113 kg
113 kg
113 kg
Platform extended
Extension
Platform
only
only
2
2
2
2
2
4
3
2
9