Check condition of vibration dampers
Replace air filter element
Measure alternator insulation resistance
Check glycol level in coolant (1)
Check PH level of engine coolant (1)
Replace safety cartridge
Replace crankcase breather filter
Check and adjust engine inlet and outlet valves (2)
Check alternator and starter motor
Check electrical system for security of cables and wear
Inspection by Atlas Copco Service technician
Notes:
In highly dusty environments, these service intervals do not apply. Check and/or replace filters and clean radiator on a regular basis.
(1) Change coolant every 5 years.
(2) Gaskets rocker cover can be re-used. New gasket can be ordered with partnumber 2914 9846 00.
Generators in standby application have to be tested on a
regular basis. At least once a month the engine should run
!
for minimum 30 minutes at a high load (50%-70%) that
the engine reaches its operating temperature.