Power circuit
Circuit-breaker, 3ph.
Number of poles
Thermal release It (thermal release is higher at 25°C)
Magnetic release Im
Circuit-breaker, 3ph., lower voltage
Number of poles (optional)
Thermal release It (thermal release is higher at 25°C)
Magnetic release Im
Circuit-breaker, 1ph.
Number of poles (optional)
Thermal release It (thermal release is higher at 25°C)
Magnetic release Im
Fault current protection
Residual current release IDn
Insulation resistance (optional)
Outlet sockets (optional)
Following three socket configuration is possible:
1. i + ii + iii + iv
2. i + ii + iii + iv (2x)
3. i + ii + iii + iv + v
144 A
3..5xIn
252 A
3..5xIn
280 A
3..5xIn
0.030-30 A
10-100 kOhm
i) domestic
2p + PE
16 A/230 V
ii) CEE form
3p + N + PE
16 A/400 V
iii) CEE form
3p + N + PE
32 A/400 V
iv) CEE form
3p + N + PE
63 A/400 V
- 101 -
4
144 A
3..5xIn
3
280 A
3..5xIn
3
280 A
3..5xIn
0.030-30 A
10-100 kOhm
4
4
4