Mitsubishi Electric FR-A520-2.2K Instruction Manual page 173

Transistorized inverter, high function & low acoustic noise
Hide thumbs Also See for FR-A520-2.2K:
Table of Contents

Advertisement

Function list (The following specifications apply to the external operation mode.)
z
Load Torque High-Speed
Pr. 270 Setting
Frequency Control
0
1
2
3
Restrictions when 1 to 3 are selected for Pr. 270
z
Under the following conditions, the functions of Pr. 270 settings "1 to 3" are made invalid:
·
PU operation
·
Programmed operation
·
PU + external combined
·
PID control
·
Remote setting function mode
·
Orientation control (option FR-A5AP)
·
Jog operation (common to PU and external operations)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Stop-On-Contact Control
×
×
{
×
{
×
{
{
: Indicates that the function is valid.
{
160
PARAMETERS
Multi-Speeds (7 speeds)
{
{
{
{