A-4

2. Output Studs

Connect the work cables to the "To Work" stud on
the front of the AC-1200. Connect the electrode
cables to the "Min", "Med" or "Max" studs for the
output desired. Actual current ranges for each stud
are indicated on the nameplate above each stud.
Recommended cable sizes are listed below. Both
the "To Work" and "Max" studs have two terminals
to simplify connection of recommended cables in
parallel. Tighten the nuts with a wrench.
Select cables required for combined work and elec-
trode cable lengths up to 150ʼ from the following
table:
Duty
Cycle
One 4/0
Two 4/0
100%
500
80%*
560
1040
* Based on 10 minute cycle.
Maximum Allowable Current for Copper Welding Cable
Cables in accessory kit recommended below have
terminals as required to comply with applicable
U.L. standards for safety.
150ʼ combined length electrode and work cables.

3. Auxiliary Power

920 volt-amperes of 115 volt AC power are avail-
able from #31 and #32 on the AC-1200 terminal
strip.

DUTY CYCLE

The AC-1200 is rated for 100% duty cycle at 1200
amps and 44 volts.
INSTALLATION
Three 4/0
Four 4/0
930
1150
1350
1290
1510