Connecting Analog Input Signals - National Instruments DAQPad-1200 User Manual

Multifunction i/o card for the pcmcia bus
Table of Contents

Advertisement

Chapter 3
Connecting the Signals
Pins
Signal Name
44
GATB1
45
CLKB1
46
OUTB2
47
GATB2
48
CLKB2
49
+5 V
50
DGND
* Indicates that the signal is active low.
AI = Analog Input
AO = Analog Output

Connecting Analog Input Signals

Caution
Exceeding the input signal range distorts input signals. Exceeding the maximum
input voltage rating may damage the DAQCard-1200 and the computer. NI is not liable for
damage resulting from such signal connections.
DAQCard-1200 User Manual
Table 3-1. Signal Descriptions (Continued)
Direction
Reference
DI
DGND
DI
DGND
DO
DGND
DI
DGND
DI
DGND
DO
DGND
N/A
N/A
DI = Digital Input
DIO = Digital Input/Output
DO = Digital Output
N/A = Not Applicable
The connector pins are grouped into AI signal pins, AO signal pins, DIO
signal pins, TIO signal pins, and power connections. Signal connection
guidelines for each group is described in the following sections.
Pins 1 through 8 are analog input signal pins for the 12-bit ADC. Pin 9,
AISENSE/AIGND, is an analog common signal. You can use this pin as a
signal ground connection to the DAQCard-1200 in RSE mode or as a return
path in NRSE mode. Pin 11, AGND, is the bias current return point for
differential measurements. Pins 1 through 8 are tied, through 4.7 kΩ series
resistances, to the eight single-ended AI channels of the input multiplexer.
Pins 2, 4, 6, and 8 are also tied to an input multiplexer for DIFF mode.
The signal ranges for inputs ACH<0..7> at all possible gains are shown in
Table 3-2. Exceeding the input signal range does not damage the input
circuitry as long as the maximum input voltage rating of ±35 V powered on
and ±25 V powered off is not exceeded. The DAQCard-1200 is guaranteed
to withstand inputs up to the maximum input voltage rating.
Gate B1—External control signal for gating counter B1.
Clock B1—External control clock signal for counter B1.
Counter B2—Voltage output signal of counter B2.
Gate B2—External control signal for gating counter B2.
Clock B2—External control clock signal for counter B2.
+5 Volts—Fused for up to 1 A of +5 V supply, but limit
current to 250 mA.
Digital Ground—Voltage ground reference for the digital
signals and the +5 V supply.
3-4
Description
ni.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Daqcard-1200

Table of Contents