Assembling The Poe Connector - Siemens RUGGEDCOM WIN5149 Installation Manual

Hide thumbs Also See for RUGGEDCOM WIN5149:
Table of Contents

Advertisement

Chapter 2
Installing the Subscriber Unit
Figure 10: Typical Outdoor Installation
1. RUGGEDCOM WIN5149    2. Shielded Cable    3. Ground Connection    4. Lightning Protector    5. RUGGEDCOM RP100/RP110    6. Drain
Wire (Shielded)
For more information about the RUGGEDCOM RP100 or RP110, refer to the RUGGEDCOM RP100 Installation Guide
or the RUGGEDCOM RP110 Installation Guide.
Section 2.8.4

Assembling the PoE Connector

A custom PoE cable with a special RJ45 connector is required to connect a PoE injector to the DC/ETH port. The
following materials and tools are required:
• The RJ45 connector kit (included). Contains an RJ45 connector and loading bar.
• CAT-5e cable of suitable length for your application. For information on cable specifications, refer to
Section 4.6, "IDU to ODU Cable
• Standard cable splicing tools, including a standard crimp tool.
To assemble the PoE connector, do the following:
1.
Slide the connector components on to the wire.
Figure 11: Assembling the Connector Components
1. Plug Housing    2. Dust Cover
2.
Strip the wire jacket 38 mm (1.5 in) from the tip, making sure not to cut the foil or drain wire.
20
1
6
3
Specifications".
2
4
3
1
2
RUGGEDCOM WIN5149
Installation Guide
5
3
Assembling the PoE Connector

Advertisement

Table of Contents
loading

Table of Contents