Electromagnetic Compatibility Guidelines - National Instruments NI 9401 Getting Started Manual

8 dio, 5 v/ttl, bidirectional, 100 ns
Table of Contents

Advertisement

and is suitable for use in Zone 2 hazardous locations, in ambient
temperatures of -40 °C ≤ Ta ≤ 70 °C. If you are using the NI 9401
in Gas Group IIC hazardous locations, you must use the device in
an NI chassis that has been evaluated as Ex nC IIC T4, Ex IIC
T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.
Caution
disturbances do not exceed 140% of the rated voltage.
Caution
not more than Pollution Degree 2, as defined in
IEC 60664-1.
Caution
ATEX/IECEx-certified enclosure with a minimum
ingress protection rating of at least IP54 as defined in
IEC/EN 60079-15.
Caution
accessible only by the use of a tool.

Electromagnetic Compatibility Guidelines

This product was tested and complies with the regulatory
requirements and limits for electromagnetic compatibility (EMC)
stated in the product specifications. These requirements and
6 | ni.com | NI 9401 Getting Started Guide
You must make sure that transient
The system shall only be used in an area of
The system shall be mounted in an
The enclosure must have a door or cover