Philips M32 107E4 GS 3 Service Manual page 16

17" auto scan colour monitor
Table of Contents

Advertisement

M32 107E4 GS_3
16
Go to cover page
4. Main panel with Bottom Tray
- Disconnect the degaussing coil (1113)from Main panel
as shown in Fig. 6.
- Remove the video panel from CRT neck.
- Remove the "screw" of I/F cable from Main panel, grounding screw
, wire as shown in Fig. 7..
- Disconnect the CRT ground "1703" from Video panel.
- Disconnect the Hi-Pot cap from CRT as shown in Fig. 8..
- Disconnect yoke wire from "1601"(on Main Panel).
- Disconnect concellation connector "1402" (on Main Panel).
- Disconnect connector "1604" and all the wires as shown in Fig. 9.
- Disconnect connector of "1802".
- Remove main panel with bottom tray as shown in Fig. 10 to Fig. 14.
=======>
=======>
(1113)
screw - grounding
Mechanical Instructions
Fig. 6
Fig. 7
Hi-Pot cap
Fig. 8
(1604)
Press
Pull-up a little bit
Press
Fig. 12
Fig. 9
Fig. 10
Fig. 11
Left &
Right
Fig. 13
Pull-up
Fig. 14