Toshiba RAV-GM901KRTP Series Service Manual page 45

Table of Contents

Advertisement

Lamp indication
Ready
Timer Operation
Alternate flash
Ready
Timer Operation
Alternate flash
Ready
Timer Operation
Simultaneous flash
Ready
Timer Operation
Simultaneous flash
Ready
Timer Operation
Flash
Ready
Timer Operation
Simultaneous flash
Ready
Timer Operation
Simultaneous flash
∗1: These are representative examples and the check code differs according to the outdoor unit to be combined.
Check code
F01
Heat exchanger sensor (TCJ) error
F02
Heat exchanger sensor (TC) error
F10
Heat exchanger sensor (TA) error
F04
Discharge temp. sensor (TD) error
F06
Temp. sensor (TL, TS, TE) error
F07
Temp. sensor (TD) error
F08
Temp. sensor (TO) error
F12
Temp. sensor (TS) error
F13
Heat sink sensor (TH) error
F15
Temp. sensor miswiring (TE, TS)
F29
Indoor EEPROM error
F31
Outdoor EEPROM error
H01
Compressor break down
H02
Compressor lock
H03
Current detection circuit error
H04
Case thermostat worked.
L03
Duplicated master indoor units
There is indoor unit of group
L07
connection in individual indoor unit.
L08
Unsetting of group address
Missed setting
L09
(Unset indoor capacity)
L10
Unset model type (Service board)
L20
Duplicated indoor central addresses
Temp. sensor (TH) error
EEPROM error
Communication between outdoor MCU
L29
Heat sink overheat error
Gas leak detection error
4-way valve error
L30
Outside interlock error
- 45 -
Cause of trouble occurrence
Indoor unit sensor error
Sensor error of outdoor unit
Outdoor compressor system error
} Power supply, outdoor P .C. board error
} Compressor overheat, outdoor wiring error
→ AUTO address
∗ If group construction and address
are not normal when power supply
turned on, automatically goes to
address setup mode.
∗1
∗1