Detection range of Occupancy sensor
Side view
6 m
90°
NOTE:
• Since Occupancy sensor detects infrared light given out by people,
the detection may be incorrect in the following situations.
Situations in which the sensor may detect no one in the room,
even when there is someone there:
• When the room temperature is high and the difference with people's
body temperature is small. (Such as when the temperature is 30˚C
or higher in summer.)
• When someone in the room do not move for a long time.
• When someone is hidden behind a sofa, other furniture, glass, or in
similar situations.
• When someone is wearing extremely thick clothing and turn their
backs on the sensor.
Situations in which the sensor may detect people in the room, even
when there is no one there
• When there is a dog or a cat moving around in the room.
• When wind is moving curtains or plants.
• When heating units, humidifiers, or electric appliances such as
oscillating electric fans are operating.

7.3. Fan control for energy saving

In the Cooling operation, when the room
temperature reaches the set temperature, the
indoor unit fan rotates intermittently to save
power. (This function is deactivated at the time of
purchase.)
To change the setting, use the following
steps;
1. Press
until only the clock is displayed on the remote
controller display.
2. Press down
for more than 5 seconds.
The current Fan Control status (
3. Press
to switch between activated (
deactivated (
).
4. Press
to send the setting to the indoor unit.
The display will return to the original screen.
NOTE:
• If you do not press any buttons for 30 seconds after
will turn off. In this case, repeat the setting from step 2.

7.4. Demand Response

This product is designed to be compatible with Air Conditioning Demand
Response program.
To utilize the function, you need a separate arrangement with your
electricity supplier. Check availability in the place of use.
When your electricity supplier activates one of the following 3 Demand
Response (DR) modes, the air conditioner switches over to the
appropriate operation.
During the DR mode, [ ] indicator on the indoor unit will blink.
Blinking pattern and the intervals are as follows:
Operation mode
Auto/Cooling/Heating/Dry/Fan
10˚C Heat operation
When the DR mode finishes, the air conditioner returns to the operation
set before entering the DR mode.
Top view
6 m
50°
50°
) is displayed.
) or
is displayed,
Indicator lamp blinking pattern
On
Blinks (2 times)
Off
Blinks (2 times)
■ Details on Demand Response mode
DR mode
Description of operation in this mode
DR mode 1
Compressor off.
Electrical energy consumption in 30 minutes:
DR mode 2
50 % or less
(compared with rated energy consumption)
Electrical energy consumption in 30 minutes:
DR mode 3
75 % or less
(compared with rated energy consumption)
NOTES:
• During the DR mode, the cooling or heating performance may be
reduced.
• During the DR mode, only the following operations are valid.
- Turning off the operation by
- Off timer operation
• The Powerful operation is performed within the operable range of
the DR mode.
• During the DR mode, the Filter sign will not display.
• Timer setting error indicator will be prioritized over the DR mode
indicator.
If you have operational issues:
(1) Contact your electricity supplier to check whether they are activating
the DR mode.
(2) Is the air conditioner under the Demand controlling?
Yes
Contact your electricity supplier.
No • Contact Fujitsu General (AUST.) PTY LIMITED. (Refer to
your warranty card.)
or
• Visit our website (www.fujitsugeneral.com.au).

8. OTHER OPERATIONS

8.1. Powerful operation

In the Powerful operation, the air conditioner will operate at maximum
power and strong airflow to cool down or warm up the room quickly.
NOTE:
• In the multi-split connection, this function cannot be used.
Press
to activate/deactivate the Powerful operation.
)
When activated, the indoor unit will emit 2 short beeps.
When deactivated, the indoor unit will emit 1 short beep.
The Powerful operation will be turned off automatically in the following
situations:
• The Powerful operation runs for a certain amount of time and the
room temperature reaches the set temperature in the Cooling, Dry,
or Heating mode.
• 20 minutes after the Powerful operation has started.
NOTES:
• The airflow direction and the fan speed are controlled automatically.
• The Powerful operation cannot be performed simultaneously with
Economy operation.
• The Powerful operation overrides the following operations. If
the following operations are set, they will start after the Powerful
operation finishes.
- Outdoor Unit Low Noise operation
- Energy Saving program
• If the wired remote controller (optional) is connected, this function is
restricted.