Fujitsu AIRSTAGE ASTH09KMTD Operation Manual

Air conditioner wall-mounted type

Advertisement

Quick Links

OPERATION MANUAL
AIR CONDITIONER
Wall-Mounted type
□ ASTH09KMTD
□ ASTH12KMTD
MODEL:
* Check the model name.
(Refer to the rating label.)
R32
REFRIGERANT
This Air Conditioner contains and
operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
PART No. 9387602456-01
Before using this product, read these instructions
thoroughly. Also, keep this manual for future
reference, together with the installation manuals
for the indoor and outdoor units.

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu AIRSTAGE ASTH09KMTD

  • Page 1 OPERATION MANUAL AIR CONDITIONER Wall-Mounted type □ ASTH09KMTD □ ASTH12KMTD MODEL: * Check the model name. (Refer to the rating label.) REFRIGERANT This Air Conditioner contains and operates with refrigerant R32. THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL. Before using this product, read these instructions Refer to Commonwealth, State, Territory and local legislation, regulations, codes, installation &...
  • Page 2: Table Of Contents

    Contents Explanation of symbols displayed on the indoor unit or outdoor unit. WARNING 1. SAFETY PRECAUTIONS .......... 1 This symbol shows that this product uses a low 2. PREPARATION ............2 burning velocity material. If the refrigerant is leaked and exposed to an external ignition source, there is a 3.
  • Page 3: Preparation

    WARNING CAUTION • This product is not intended for use by persons • Do not touch the aluminum fins of heat exchanger (including children) with reduced physical, sensory built-in this product to avoid personal injury when you or mental capabilities, or lack of experience and maintain the unit.
  • Page 4: Name Of Parts

    3. NAME OF PARTS 3.2. Remote controller When you use the optional remote controller, the appearance CAUTION and the operation procedure may differ. For details, refer to the operation manual of each remote For appropriate signal transmission between the remote controller.
  • Page 5 CAUTION • To prevent malfunction or damage of the remote controller: - Place remote controller at where will not be exposed to direct sunlight or excessive heat. - Remove batteries if the product is not going to be For Powerful operation ....Refer to page 8. used for an extended period.
  • Page 6: Inserting Batteries

    3.3. Inserting batteries 4. BASIC OPERATIONS Battery type: R03/LR03/AAA x 2 ■ 3 steps to start operation 1. Press to start or stop the operation. 2. Press to select the operation mode. The operation mode changes as follows. AUTO COOL HEAT 3.
  • Page 7: Timer Operations

    ■ Airflow direction range 6.1. Weekly timer Up/down airflow direction ■ Setting details 1. Select Weekly timer in step 2 of "Timer setting procedure". 1 ⇄ 2 ⇄ 3 ⇄ 4 ⇄ 5 ⇄ 6 Change by 2. Press to select the program number and the Swing operation by day of the week.
  • Page 8: On Timer Or Off Timer

    ■ Examples of Weekly timer 7. ENERGY SAVING OPERATIONS Example 1 7:00 9:00 11:00 17:00 23:00 7.1. Economy operation Monday Program Program Program Program It saves more electricity than other operation modes by changing the set Friday temperature to a moderate setting. 26°C 28°C Press...
  • Page 9: Fan Control For Energy Saving

    Contact your electricity supplier. 7.3. Fan control for energy saving No • Contact Fujitsu General (AUST.) PTY LIMITED. (Refer to your warranty card.) In the Cooling operation, when the room • Visit our website (www.fujitsugeneral.com.au).
  • Page 10: Outdoor Unit Low Noise Operation

    8.2. Outdoor Unit Low Noise operation • To change the air conditioner custom code, contact an authorized service personnel (initially set to A). • If you do not press any buttons for 30 seconds after the custom The Outdoor Unit Low Noise operation lowers noise from the outdoor code is displayed, the display returns to the clock display.
  • Page 11 6. Dry the Ion deodorization filter in shade. Cleaning air filter 7. Set the new or washed air cleaning filters into the air 1. Open the intake grille until it snaps. cleaning filter holders. NOTE: • Use the Apple-catechin filter as soon as possible after opening the package.
  • Page 12: General Information

    ■ Indoor unit temperature and humidity range After extended non-use of the unit Permissible ranges of temperature and humidity are as follows: If you have shut down the indoor unit for 1 month or more, perform the Indoor temperature Cooling/Dry [°C] 18 to 32 Fan mode operation for half a day to dry the internal parts thoroughly...
  • Page 13: Multi-Split Type Air Conditioner

    12.2. Multi-split type air conditioner Does not operate at all. □ Has there been a power outage? In this case, the unit restarts automatically after the power supply This indoor unit can be connected to a multi-split type outdoor unit. The is resumed.
  • Page 14 ■ State of indicator lamps Noise is heard. Lighting pattern: Off, Blinking, Any state □ Is the unit operating, or immediate after stopping operation? In this case, refrigerant flowing sound may be heard. It may be particularly noticeable for 2-3 minutes after starting operation. State Causes and solutions page...

This manual is also suitable for:

Airstage asth12kmtd

Table of Contents