Advertisement

Quick Links

OPERATION MANUAL
AIR CONDITIONER (Wall-Mounted type)
□ ASTH09CNCA
□ ASTH12CNCA
MODEL:
* Check the model name.
(Refer to the rating label.)
Before using this product, read these instructions thoroughly
and keep this manual for future reference.
R32
REFRIGERANT
This Air Conditioner contains and
operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
PART No. 9333892061-01
Contents
1. SAFETY PRECAUTIONS .......................................... 1
2. PREPARATION ......................................................... 2
2.1. Inserting batteries ............................................. 3
3. NAME OF PARTS ..................................................... 3
3.1. Indoor unit ........................................................ 3
3.2. Remote controller ............................................. 3
4. BASIC OPERATIONS ............................................... 5
5. AIRFLOW SETTINGS ............................................... 5
5.1. Fan speed setting ............................................. 5
5.2. Airflow direction setting .................................... 5
6. TIMER OPERATIONS ............................................... 5
6.1. On timer or Off timer ......................................... 6
6.2. Program timer ................................................... 6
6.3. Sleep timer ...................................................... 6
7. ENERGY SAVING OPERATIONS ............................ 6
7.1. Economy operation .......................................... 6
7.2. Fan control for energy saving ........................... 6
7.3. Demand Response ........................................... 6
8. OTHER OPERATION ................................................ 7
8.1. Powerful operation ........................................... 7
9. SETTINGS ON INSTALLATION ................................ 7
10. CLEANING AND CARE ............................................. 7
11. GENERAL INFORMATION ....................................... 9
12. OPTIONAL PARTS ................................................... 9
12.1. Wired remote controller .................................... 9
13. TROUBLESHOOTING .............................................. 9

1. SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section
carefully before you use this product, and be sure to comply
with the following safety precautions.
Incorrect operation due to failure to follow the instructions may
cause harm or damage, the seriousness of which is classified
as follows:
This mark warns of death or serious injury.
This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.
This mark denotes an action that is COMPULSORY.
En-1
WARNING
CAUTION

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu AIRSTAGE ASTH09CNCA

  • Page 1: Table Of Contents

    OPERATION MANUAL Contents 1. SAFETY PRECAUTIONS .......... 1 AIR CONDITIONER (Wall-Mounted type) 2. PREPARATION ............2 2.1. Inserting batteries ..........3 3. NAME OF PARTS ............. 3 3.1. Indoor unit ............3 3.2. Remote controller ..........3 4. BASIC OPERATIONS ..........5 5.
  • Page 2: Preparation

    Explanation of symbols displayed on the indoor unit or outdoor unit. WARNING WARNING • Do not start or stop the operation of this product by This symbol shows that this product uses a low inserting or pulling out the power plug, or by turning burning velocity material.
  • Page 3: Inserting Batteries

    3.1. Indoor unit CAUTION • If leaking battery fluid comes in contact with your skin, For Manual Auto operation eyes, or mouth, immediately rinse with plenty of clean and Filter indicator reset (Refer to page 10.) water, and consult your physician. •...
  • Page 4 : The setting must be done while the setting screen is Remote controller display displayed for each function. In this section, all the possible indicators are displayed for : The button is controllable only when the air conditioner is description. In actual operation, the display is linked with the operating.
  • Page 5: Basic Operations

    ■ Airflow direction range 4. BASIC OPERATIONS Up/down airflow direction ■ 3 steps to start operation Change by 1 ⇄ 2 ⇄ 3 ( ⇄ 4 ⇄ 5 ⇄ 6) Cooling, Dry 1. Press to start or stop the operation. 1 ⇄...
  • Page 6: On Timer Or Off Timer

    6.1. On timer or Off timer 7. ENERGY SAVING OPERATIONS 1. Select On timer or Off timer in step 1 of “Timer setting 7.1. Economy operation procedure.” 2. Each time you press , the time changes It saves more electricity than other operation modes by changing the set as follows: temperature to a moderate setting.
  • Page 7: Other Operation

    Contact your electricity supplier. No • Contact Fujitsu General (AUST.) PTY LIMITED. (Refer to 10. CLEANING AND CARE your warranty card.) • Visit our website (www.fujitsugeneral.com.au).
  • Page 8 5. Rinse the Ion deodorization filter with water flow. Cleaning indoor unit body 6. Dry the Ion deodorization filter in the shade. NOTES: 7. Set the new or washed air cleaning filters into the air • Do not use water hotter than 40°C. cleaning filter holders.
  • Page 9: General Information

    Additional inspection 12. OPTIONAL PARTS After long period of use, accumulated dust inside the indoor unit may reduce the performance even if you have maintained the unit properly. 12.1. Wired remote controller In such a case, a product inspection is recommended. For more information, consult authorized service personnel.
  • Page 10 Timer setting error because of Auto restart Humidity does not drop during the Dry operation. ⇒ Reset the clock and timer settings. □ You cannot set the target humidity in the Dry mode. If you feel high humidity, set the temperature lower. Test run operation (for authorized Airflow is weak or stops.

This manual is also suitable for:

Airstage asth12cnca

Table of Contents