Fujitsu AOUG12LZAH1 Service Manual page 133

Hide thumbs Also See for AOUG12LZAH1:
Table of Contents

Advertisement

 Model: AOUG15LZAH1
Fan speed is defined by outdoor temperature and compressor frequency.
• Outside air temperature zone selection
Fan step
S-HIGH2
S-HIGH1
HIGH
10
9
8
7
6
5
4
3
2
1
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 1,100 rpm
3-2. Outdoor fan control
Outside air
temperature rises
21°C
12°C
2°C
Cooling
Heating
Y zone
1,100
1,050
1,100
1,050
1,100
1,100
1,050
1,100
840
920
750
920
690
710
560
620
440
560
440
500
440
440
440
440
Outside air
temperature drops
Y zone
Z zone
F zone
G zone
Dry
Cooling or dry at low outdoor temp.
Y zone
Z zone
1,050
850
840
850
750
770
690
630
560
440
440
320
440
320
440
320
440
320
- (04-15) -
19°C
10°C
0°C
Unit: rpm
F zone
G zone
320
320
320
270
270
270
270
270
270
270
270
270
230
230
230
230
230
230
3. Fan control

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aoug09lzah1Aoug15lzah1Asug09lzasAsug12lzasAsug15lzas

Table of Contents