Left Side; Right Side - Fisher & Paykel SINGLE DISHDRAWER DD60SC9 Installation Manual

Hide thumbs Also See for SINGLE DISHDRAWER DD60SC9:
Table of Contents

Advertisement

Hose and cord lengths
Your services can be installed to either the left-hand or right-hand side
z
of the product in an adjacent cabinet. Refer to 'Cabinetry preparation'
for service access requirements.
If the drain hoses supplied are not long enough to reach your services,
z
you may purchase a Fisher & Paykel drain hose extension kit which will
extend the drain hoses by 3.6m (part number 525798).
Water connection
Recommended water temperature: Hot (maximum 60°C)
z
Supplied hose to suit 3/8" male compression fitting.
z
Ensure water connection complies with local plumbing regulations.
z
Water pressure
Water softener models: max. 1 MPa (145 psi), min. 0.1 MPa (14.5 psi)
z
Non-water softener models: max. 1 MPa (145 psi), min. 0.03 MPa (4.3 psi)
z
Electrical requirements
220 – 240VAC min 4.2A
z
PLUMBING & ELECTRICAL CONSIDERATIONS
d
e
f
SERVICE DIMENSION
A Length of drain hoses
B Length of power cord**
C Length of inlet hose
D Distance from floor to top of hose support
E Minimum distance from floor to end of drain hoses***
F Minimum inlet hose radius
G Maximum distance from cabinetry centre of electrical outlet
*dimensions taken from the chassis edge where applicable
**excluding plug
***standpipe install illustrated. Distance is the same for all plumbing installs.
c
b
a
d
e
f
a
b c

LEFT SIDE*

RIGHT SIDE*

MM
MM
2000
1800
1650
1650
1650
1250
750 – 883
750 – 883
500
500
200
200
450
450
9