Water Supply - Scotsman Prodigy ELITE MC222 ECC Installation And User Manual

Remote low side modular cube with condensing unit
Table of Contents

Advertisement

MC222 and Condensing Unit
Remote Low Side User Manual

Water Supply:

A 3/8" flare nut on tubing is located at the top panel,
near the refrigeration tubing.
Inside the hardware bag, inside the cabinet, a
3/8" inch double male flare adapter (flare union) is
supplied. Use the supplied adapter to make a 3/8"
male flare fitting for the water inlet.
Connect a cold, potable water supply to the 3/8" water
inlet fitting installed above. Use 3/8" OD copper or
other comparable sized tubing for the water supply.
Note: This is an NSF listed ice machine and contains
provisions for back-flow prevention in its design. No
external back flow preventer is required.
Communication Cable
Suction Line Insulation
Water Supply Connection
June 2022
Page 14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prodigy elite a series

Table of Contents