IMPORTANT:
If the lid must remain open in order to move the printer through a narrow door, do not pull or push the printer
directly using the open lid, as this may cause the hinges to deform, and the top lid may become misaligned.
Doorway specifications with top cover open and closed, and rear parts removed
Minimum doorway width
Minimum doorway height
Floor characteristics
Minimum load-bearing: withstand printer's weight of 643 kg (1418 lb)
●
Flat and horizontal
●
Solid, smooth, and level
●
Electrostatic-free surface
●
Easy to clean
●
Material spilled on the floor can be slippery: take care to keep the floor clean around the printing area.
Avoid installing the printer near heavy equipment that may cause floor vibration.
Environmental specifications and considerations
Ensure that the room in which the printer is installed meets local environmental, health, and safety (EHS)
guidelines and regulations.
Environmental requirements
Operating temperature
Operating humidity
Ventilation for operator comfort
ENWW
Hold the printer using the handles, and always move the printer with the top lid closed if possible.
Specification
20–30°C (68–86°F)
20–70% RH without condensation
At least 5 air changes per hour, regardless of
room size
Optimum 10 air changes per hour for
operator comfort
Top cover closed
895.5 mm (35.3 in)
1505 mm (59.25 in)
Top cover open
850.2 mm (33.5 in)
2015 mm (79.33 in)
Comments
HVAC system should accommodate printer
heat generation to maintain this
temperature range. See heat considerations
below.
Printer not recommended for rooms smaller
than 35 cubic meters (1236 cubic feet)
Floor characteristics
9