Bryant 926TC Installation, Start-Up, Operating And Service And Maintenance Instructions page 35

Two-stage, non-communicating, variable 25-speed, ecm multipoise, condensing gas furnace with intelisense
Table of Contents

Advertisement

926TC: Installation, Start-up, Operating and Service and Maintenance Instructions
NOTE: The following is based upon National codes for gas appliances and is provided as a reference.
Refer to local codes which may supersede these standards and/or recommendations.
Item
Clearance Description
Clearance above grade, veranda, porch, deck, balcony
A
or anticipated snow level
B
Clearance to a window or door that may be opened
C
Clearance to a permanently closed window
Vertical clearance to a ventilated soffit located above
D
the terminal within a horizontal distance of 2 feet (61
cm) from the centerline of the terminal
E
Clearance to an unventilated soffit
F
Clearance to an outside corner
G
Clearance to an inside corner
Clearance to each side of the centerline extended
H
above electrical meter or gas service regulator
assembly
I
Clearance to service regulator vent outlet
Clearance to non—mechanical air supply inlet to
J
building or the combustion air inlet to any other
appliance
K
Clearance to a mechanical air supply inlet
L
Clearance under a veranda, porch, deck, or balcony
Clearance to each side of the centerline extended
above or below vent terminal of the furnace to a dryer
M
or water heater vent, or other appliance's direct vent
intake or exhaust
Clearance to a moisture exhaust duct
N
(dryer vent, spa exhaust, etc.)
0
Clearance from a plumbing vent stack
Clearance above or adjacent to paved sidewalk or
P
paved driveway located on public property
> greater than, ≥ greater than or equal to, < less than, ≤ less than or equal to
NOTE:
1.
In accordance with the current CAN/CSA B149.1, Natural Gas and Propane Installation Code.
2.
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
3.
NOTE: This table is based upon National codes for gas appliances, and are provided as a reference.
Refer to Local codes which may supersede these standards and/or recommendations.
4.
For clearances not specified in ANSI Z223.1/NFPA 54 or CAN/CSA B 149.1, clearances shall be in accordance with local installation codes and the requirements of the gas supplier and
the manufacturer's installation instructions.
5.
When locating vent terminations, consideration must be given to prevailing winds, location, and other conditions which may cause recirculation of the combustion products of adjacent
vents. Recirculation can cause poor combustion, inlet condensation problems, vent termination icing, and/or accelerated corrosion of the heat exchangers.
6.
Design and position vent outlets to avoid ice build-up on and moisture damage to surrounding surfaces.
7.
The vent for this appliance shall not terminate:
a. Near soffit vents of crawl space vents or other areas where condensate or vapor could create a nuisance or hazard or property damage; or
b. Where condensate vapor could cause damage or could be detrimental to the operation of regulators, relief valves, or other equipment.
8.
These National standards apply to all non-direct-vent gas appliances. Contact Local code officials for additional requirements and/or exclusions.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Fig. 43 – Ventilated Combustion Air and Non-Direct Vent Termination Clearance
12 in. (305 mm) for appliances >10,000 BTUh (3 kW)
36 in. (914 mm) for appliances >100,000 BTUh (30 kW)
For clearances not specified in ANSI Z223.1/NFPA 54 or CAN/CSA B149.1, clearances shall be in
accordance with local installation codes and the requirements of the gas supplier and the manufacturer's
12 in. (305 mm) for appliances >10,000 BTUh(3 kW)
36 in. (914 mm) for appliances >100,000 BTUh (30 kW)
Permitted only if veranda, porch, deck, or balcony is
fully open on a minimum of two sides beneath the floor.
Vent shall not terminate above or adjacent to a sidewalk
or paved driveway that is located between two
single-family dwellings and serves both dwellings.
V
V
(1 )
Canadian Installations
(per CAN/CSA B149.1)
12 in. (305 mm)
18 in. (457 mm) above roof surface.
and </=100,000 BTUh (30 kW),
installation instructions.
Manufacturer's Recommendation: See Notes 3-8.
3 ft. (.9 M) within 15 ft. (4.6 M)
above the meter/regulator assembly.
3ft. (.9 M)
and </= 100,000 BTUh (30 kW),
6 ft. (1.8 M)
12 in. (305 mm).
12 in. (305 mm)
12 in. (305 mm) See Note 4
3 ft. (.9 M)
7 ft. (2.1 M).
35
(2 )
U.S. Installations
(per ANSI Z223.1/NFPA 54)
12 in. (305 mm)
4ft. (1.2M) below or to the side of the opening,
1 ft (.3M) above the opening.
Manufacturer's Recommendation: See Note 8.
3 ft. (.9 M) within 15 ft. (4.6 M)
above the meter/regulator assembly.
See Note 4.
4ft. (1.2M) below or to the side of the opening,
1 ft (.3M) above the opening.
Manufacturer's Recommendation: See Note 8
3ft. (.9 M) above if within 10 ft. (3 M) horizontally
See Note 4.
Manufacturer's Recommendation: See Notes 3-8.
12 in. (305 mm)
12 in. (305 mm) See Note 4
3 ft. (.9 M)
7ft. (2.1M)
A12325