Bryant 915SA Product Data

Bryant 915SA Product Data

915sa 95 afue legacy line single-stage 4-way multipoise condensing gas furnace

Advertisement

915SA 95 AFUE
LEGACY LINE SINGLE- -STAGE
4- -WAY MULTIPOISE
CONDENSING GAS FURNACE
The 915S Multipoise Condensing Gas Furnace is part of the
Legacy Line product offering. Sporting a PSC blower motor and
an Annual Fuel Utilization Efficiency (AFUE) of 95.5%, this
single-stage
gas
furnace
homeowners. This Legacy Line Gas Furnace also features 4-way
multipoise installation flexibility, and is available in nine model
sizes. The 915S can be vented for direct vent/two-pipe, ventilated
combustion air, or single-pipe applications. A BryantR Air
Conditioner or Heat Pump can be used to form a complete system.
All units meet California Air Quality Management District
emission requirements. These furnaces are approved for
Manufactured Housing (Mobile Home) applications. All sizes are
design certified in Canada.
STANDARD FEATURES
S 4-way multipoise design for upflow, downflow or horizontal
installation.
S Optional through-the-cabinet downflow venting.
Product Data
provides
efficient
comfort
Use of the AHRI Certified
manufacturer's participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
S Installation flexibility with a 360-degree rotating elbow.
S Ideal condensing furnace height 35" cabinet: short enough for
taller coils, but still allows enough room for service.
S Silicon Nitride Perfect Lightt Hot Surface Igniter.
S Aluminized-steel primary heat exchanger.
S Stainless-steel condensing secondary heat exchanger.
S High-quality corrosion-resistant prepainted steel cabinet with
hemmed edges for safety.
S Factory-configured ready for upflow applications.
S Direct-vent/sealed combustion, single-pipe venting or ventilated
combustion air.
S PSC blower motor, single-speed inducer motor, and single-stage
gas valve.
S Self-diagnostics
S Approved for Twinning applications (42060 through 60120
sizes, only).
S Propane convertible (See accessory list).
S Approved for Manufactured Housing/Mobile Home applications
A11264
(except 140,000 Btuh input) with MH accessory kit.
S Convenient Air Purifier and Humidifier connections.
S Residential installations may be eligible for consumer financing
through the Retail Credit Program.
S Certified to leak 2% or less of nominal air conditioning CFM
for
delivered when pressurized to 1-inch water column with all
present air inlets, air outlets, and condensate drain port(s) are
sealed.

LIMITED WARRANTY*

S 10 year parts and lifetime heat exchanger limited warranty to the
original purchaser upon timely registration.
S Limited warranty period is five years for parts and twenty years
for the heat exchanger if not registered within 90 days of
installation.{
* For owner occupied, residential applications.
Jurisdictions where warranty benefits cannot be conditioned on registra-
{
tion will receive registered limited warranty benefits.
Mark indicates a
TM
1
CERTIFIED

Advertisement

Table of Contents
loading

Summary of Contents for Bryant 915SA

  • Page 1: Limited Warranty

    915SA 95 AFUE LEGACY LINE SINGLE- -STAGE 4- -WAY MULTIPOISE CONDENSING GAS FURNACE Product Data S Installation flexibility with a 360-degree rotating elbow. S Ideal condensing furnace height 35” cabinet: short enough for taller coils, but still allows enough room for service. S Silicon Nitride Perfect Lightt Hot Surface Igniter.
  • Page 2: Features And Benefits

    Power Heatt Igniter — Bryant’s unique SiN igniter is not only Monoport Burners — The burners are specially designed and physically robust but it is also electrically robust. It is capable of...
  • Page 3: Specifications

    SPECIFICATIONS Heating Capacity and Efficiency 30040 30060 42060 48080 60080 42100 60100 60120 60140 Input High (BTUH) 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 140,000 Heat Output High (BTUH) 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 135,000 Heat Efficiency AFUE % (ICS) 95.5...
  • Page 4: Parts List

    MODEL NUMBER NOMENCLATURE 1 - 2 6 - 7 8 - 10 12 - 13 Family/Tier Base Eff. Htg. Stages Major Series Htg. Cap. Motor Width Clg. Cap. Voltage Minor Series Features 91 - Legacy 0 --- 90 AFUE 92 - Preferred 3 --- 93 AFUE 98 - Evolution 5 --- 95 AFUE...
  • Page 5 ACCESSORIES Venting Accessories Part Number Used With Notes Vent Kit - Through the Cabinet KGADC0101BVC 2-in. KGAVT0701CVT See Venting Tables Vent Terminal - Concentric 3-in. KGAVT0801CVT See Venting Tables 2-in. KGAVT0101BRA See Venting Tables 1, 2 Vent Terminal Bracket 3-in. KGAVT0201BRA See Venting Tables 1, 2...
  • Page 6 AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) EXTERNAL STATIC PRESSURE (IN. W.C.) UNIT RETURN-AIR SPEED SIZE CONNECTION TAPS Black 1100 1055 1010 Yellow 30040 SIDE/BOTTOM Blue Black 1340 1295 1245 1190 1130 1065 1005 Yellow 1035 1010 30060 SIDE/BOTTOM Blue Black...
  • Page 7 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) Table 1 – Maximum Equivalent Vent Length - - Ft. (M) 0 to 4500 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 8 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) Table 2 – Deductions from Maximum Equivalent Vent Length - - Ft. (M) Pipe Diameter (in): 1-1/2 2-1/2 Mitered 90º Elbow (2.4) (2.4) (2.4) (2.4) (2.4) Medium Radius 90º Elbow (1.5) (1.5) (1.5) (1.5) (1.5)
  • Page 9 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) (CONTINUED) Table 3 – Maximum Equivalent Vent Length - - Ft. (M) 4501 to 10,000 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 10 MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - - FT. (M) Maximum Length of Uninsulated and Insulated Vent Pipe-Ft (M) No Insulation 3/8-in. (9.5 mm) Insulation 1/2-in. (12.7 mm) Insulation Single Stage Pipe Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Winter Design Furnace Length in...
  • Page 11: Return Air Temperature

    RETURN AIR TEMPERATURE This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
  • Page 12 DOWNFLOW SUBBASE LOCATING / 4-IN. TYP PLENUM OPENING LOCATING FACTORY-SUPPLIED FIELD-INSTALLED INSULATION A97427 A88207 Assembled Disassembled DIMENSIONS (IN. / MM) PLENUM OPENING* FLOOR OPENING HOLE NO. FOR FURNACE FURNACE IN DOWNFLOW WIDTH CASING WIDTH APPLICATION ADJUSTMENT Furnace with or without Cased Coil 15--- 1/8 16--- 3/4 20--- 3/8...
  • Page 13: Typical Wiring Schematic

    MEDIA FILTER CABINET 25-5/8" (651mm) 24-1/4” 23-5/8" (616mm) (600mm) Opening with Flanges Bent 23-1/8” 23-3/8” (588mm) (594mm) Opening Duct Side Furnace Side 23-3/4” (603mm) " Centerline Screw Slots Media Filter (146mm) Cabinet 17" (432mm) 16" (406mm) 16" (406mm) 20" (508mm) 21"...
  • Page 14: Dimensional Drawing

    DIMENSIONAL DRAWING A11612...
  • Page 15: Guide Specifications

    GUIDE SPECIFICATIONS General System Description Primary Heat Exchangers Furnish a ______________________ 4- -way multipoise gas- -fired Primary heat exchangers shall be 3- -Pass corrosion- -resistant condensing furnace for use with natural gas or propane (factory- - aluminized steel of fold- -and- -crimp sectional design and applied authorized conversion kit required for propane);...
  • Page 16 Catalog No. PDS915SA ---01 E2012 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 01/12 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Table of Contents