Mitsubishi Electric PLA-A EA Series Operation Manual page 9

Table of Contents

Advertisement

Available languages

Available languages

3. Operation
3.4. Fan speed setting
Fri
83
Room
Cool
Set temp.
Auto
83
Mode
Temp.
Fan
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Press the [F4] button to go through the fan speeds in the following order.
• The available fan speeds depend on the models of connected indoor
units.
Notes:
The number of available fan speeds depends on the type of unit
connected.
In the following cases, the actual fan speed generated by the unit
will diff er from the speed shown the remote controller display.
1. W hile the display is in "Standby" or "Defrost" states.
2. W hen the temperature of the heat exchanger is low in the heat-
ing mode.
( e.g. immediately after heating operation starts)
3. I n HEAT mode, when room temperature is higher than the tem-
perature setting.
4. I n COOL mode, when room temperature is lower than the tem-
perature setting.
5. W hen the unit is in Drying mode.
3.5. Airfl ow direction setting
3.5.1 Navigating through the Main menu
<Accessing the Main menu>
Main
Main menu
Operation
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
<Item selection>
Main
Main menu
Initial setting
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Auto
Press the [MENU] button on the
Main display.
The Main menu will appear.
Press [F2] to move the cursor left.
Press [F3] to move the cursor right.
Cursor
<Exiting the Main menu screen>
Fri
83
Room
Cool
Set temp.
Auto
83
Mode
Temp.
Fan
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
If no buttons are touched for 10 minutes, the screen will automatically
return to the Main display. Any settings that have not been saved will
be lost.
<Display of unsupported functions>
Title
Not available
Unsupported function
Return: RETURN
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
3.5.2 Vane·Vent. (Lossnay)
<Accessing the menu>
Main
Main menu
Operation
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu: RETURN
Cursor
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Press the [RETURN] button to exit
the Main menu and return to the
Main display.
The message at left will appear
if the user selects a function not
supported by the corresponding
indoor unit model.
Select "Operation" from the Main
menu (refer to 3.5.1), and press the
[SELECT/HOLD] button.
Select "Vane·Louver·Vent.
(Lossnay)" from the Operation
menu, and press the [SELECT/
HOLD] button.
en
8

Advertisement

Chapters

Table of Contents
loading

Table of Contents