Mitsubishi Electric PLA-A EA Series Operation Manual page 12

Table of Contents

Advertisement

Available languages

Available languages

3. Operation
Confirmation procedure (wired remote controller)
Manual vane angle
Ref. address
Unit No.
Identify unit Check button
Input display:
SELECT
Cur.
Address
Check
F1
F2
F3
F4
RETURN SELECT
MENU
HOLD
Manual vane angle
Ref. address
Unit No.
Function setting for unit
with vane fully open.
Return:
RETURN
F1
F2
F3
RETURN SELECT
MENU
HOLD
Manual vane angle
No communication
Check Unit state.
Return:
RETURN
F1
F2
F3
3.6. 3D i-see Sensor setting
Note:
This function cannot be set depending on the outdoor unit to be
connected.
3.6.1 3D i-see Sensor setting
Main
Main menu
Operation
en
F1
F2
F3
F4
RETURN SELECT
MENU
HOLD
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu: RETURN
Cursor
F1
F2
F3
RETURN SELECT
MENU
HOLD
11
1 First, confirm by setting "Ref.
address" to 0 and "Unit No." to 1.
• Move the cursor to "Ref. address"
or "Unit No." with the [F1] button to
select.
• Select the refrigerant address and
the unit number for the units to
whose vanes are to be fixed, with
the [F2] or [F3] button, and press
the [SELECT/HOLD] button.
ON
• Ref. address: Refrigerant address
OFF
• Unit No.: 1, 2, 3, 4
Press the [F4] button to confirm
the unit.
2 Change the "Unit No." in order and
check each unit.
• Press the [F1] button to select
"Unit No.".
Press the [F2] or [F3] button to
change the "Unit No." to the unit
that you want to check, and then
press the [F4] button.
• After pressing the [F4] button, wait
F4
approximately 15 seconds, and
ON
then check the current state of the
OFF
air conditioner.
→ The vane is pointing downward.
→ This air conditioner is displayed
on the remote controller.
→ All outlets are closed. → Press
the [RETURN] button and continue
the operation from the beginning.
→ The messages shown to the
left are displayed. → The target
device does not exist at this refrig-
F4
erant address.
• Press the [RETURN] button to
return to the initial screen.
3 Change the "Ref. address" to the
next number.
• Refer to step 1 to change the
"Ref. address" and continue with
the confirmation.
1 Select "Operation" from the Main
menu, and press the [SELECT/
HOLD] button.
ON
OFF
2 Select "Comfort" from the
Operation menu, and press the
[SELECT/HOLD] button.
F4
ON
OFF
Comfort
Manual vane angle
3D i-See sensor
Setting display: SELECT
Cursor
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
3D i-See sensor
Air distribution
Energy saving option
Seasonal airflow
Setting display: SELECT
Cursor
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
3.6.2 Air distribution
Air distribution
Ref. address
Unit No.
Identify unit Check button
Input display:
SELECT
Cur.
Address
Check
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Air distribution
Ref. address
All
Unit No.
Auto vane
Direct/Indirect
Direct/Indirect setting
Select:
SELECT
Cur.
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Direct
Cooling
horizontal → swing
Heating
keep downward
3 Select "3D i-See sensor" with the
[F1] or [F2] button, and press the
[SELECT/HOLD] button.
4 Select the desired menu with the
[F1] or [F2] button, and press the
[SELECT/HOLD] button.
• Air distribution
Select the airflow direction control
method when the airflow direction
is set to "Auto".
• Energy saving option
Operates the energy-save mode
according to whether persons are
detected in the room by the 3D
i-see Sensor.
• Seasonal airflow
When the thermostat turns off, the
fan and the vanes operate accord-
ing to the control settings.
1 Move the cursor to "Ref. address"
or "Unit No." with the [F1] button to
select.
Select the refrigerant address and
the unit number for the units to
whose vanes are to be fixed, with
the [F2] or [F3] button, and press
the [SELECT/HOLD] button.
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to confirm the
unit.
The vane of only the target indoor
unit is pointing downward.
2 Select the menu with the [F4] but-
ton.
Default → Area → Direct/Indirect
→ Default...
Default: The vanes move the same
as during normal operation.
"Area"*: The vanes move to the
down airflow direction toward
areas with a high floor temperature
during cooling mode and toward
areas with a low floor temperature
during heating mode. Otherwise,
the vanes move to the horizontal
airflow direction.
"Direct/Indirect"*: The vanes
automatically move relative to the
areas where persons are detected.
The vanes operate as indicated in
the following table.
* In order to enable this function,
the airflow direction must be set to
"Auto".
Vane setting
Indirect
keep horizontal
downward → horizontal

Advertisement

Chapters

Table of Contents
loading

Table of Contents